TECHNICAL SPECIFICATION

RIVA OPEN

Model

 

 

 

 

 

16" Riva Open

 

22" Riva Open

 

24" Riva Open

26" Riva Open

28" Riva Open

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal Heat Output

 

Wood

 

kW

4

6.5

8

9

10

 

Solid Fuel

 

kW

3

4

5

5

5

 

 

 

Flue Draught at Nominal Heat

 

All Fuels

 

mm

1.25

1.25

1.25

1.25

1.25

 

 

inch Wg

0.05

0.05

0.05

0.05

0.05

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flue Gas Mass Flow

 

Wood

 

g/s

39.1

45.0

52.8

53.0

54.1

 

 

 

 

 

 

 

 

 

 

 

 

 

Solid Fuel

 

g/s

27.8

30.0

75.1

45.0

49.5

 

 

 

Flue Gas Temperature at Spigot/Socket

Wood

 

°C

200

155

165

180

220

Solid Fuel

 

°C

110

125

120

150

150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flue Outlet Size

 

 

 

mm

 

2x(120x102)

 

3x(105x105)

 

3x(122x105)

3x(138x105)

3x(138x105)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

inch

 

2x(43/4x4)

 

3x(41/8x41/8)

 

3x(413/16x41/8)

3x(57/16x41/8)

3x(57/16x41/8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

 

Std

 

kg

 

62

 

83

 

86

89

97

 

 

Low

 

kg

 

59

 

76

 

81

86

-

 

 

 

 

 

 

 

 

Wood

 

Seasoned wood (less than 20% moisture content)

 

Recommended Fuel

 

 

 

 

 

 

 

 

 

 

 

 

 

Solid Fuel

 

Briquette smokeless fuel suitable for open appliances

 

 

 

 

 

 

 

 

(Homefire - Supertherm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

As tested to the requirements of EN 13229:2001 for intermittent operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.STANDARD FEATURES

Damper Control

Primary air (under grate air for full multi-fuel use)*

* Multi-fuel kits 8705, 8710, 8720 only

2. PACKING LIST

Instructions

Guarantee card

Pair of gloves

Damper/Multi-fuel grate Tool

Poker

11

Page 11
Image 11