3.Fitting of Frames

INSTALLATION INSTRUCTIONS

2.6Or

• Fit a Multi-fuel box, Diagram 9

This must be done with the frame removed, see Section 3

9

PR8084

2.7Fit a Contemporary Multi-fuel Log bar, Diagram 10 Slide into channels in the front of the Multi-fuel Box and cutout in grates.

The removable frame base is not shown for clarity but must be in place before the Log Bar is fitted, See Section 3A.

10

PR8082

3.Fitting of Frames

3.1Brass or Brushed Steel Profil Frames

Fit the brass or brushed steel Profil Frame, Diagram 11

11

Locate the frame around the flange

Fold the tabs around the back edge of the flange - shown in detail (2 on sides and 2 on top)

3.2Arts Frames

Drill 4 Ø7.5 holes in the positions shown, Diagram 12

A 1:1 scale drilling template is provided with the frame to assist in correctly locating the holes.

 

12

 

 

 

 

 

 

16" Frame Drilling Template

 

 

 

 

 

 

 

 

18

338

 

Ø7,5THRO - 4 POS

547

 

30

20

 

434

+

 

All dims to be - 0.5mm

 

 

Attach Upper ('U' shaped) and Lower (L shaped) brackets on the front of the firebox flange using M6 Countersunk Screws and Nuts, Diagram 13

13M6

Countersunk

Screw

M6 Nut

PR8086

Line the frame up with the flange

Lower the frame over the brackets and slide into bracket slots

Check it is located securely, Diagram 14

Tab