6.FITTING AND REMOVAL OF  FLUE DAMPER

INSTALLATION INSTRUCTIONS

Position the back and side cast firebricks on the grate behind the raised ribs, See Diagram 30

30

• Slide the ashpan (G) under the grate

•Hook the front bars (H) onto the fireplace and slide the ashpan cover (F) into position below them

6.FITTING AND REMOVAL OF  FLUE DAMPER

6.1To maintain efficient combustion, the appliance is fitted with a Flue Damper System. See Diagram 31

31

6.2Allow the appliance to cool fully before removing Flue Damper.

6.3To remove the damper system, first remove the fuel kit and Frame if fitted from the appliance to give access to the firebox, See section 2-3

6.4Remove the Pivot Bolts (both sides of the firebox) while holding the Damper in position. This will allow the Damper to drop down for removal. Note the position of washers on the Pivot Bolts

32

PR8094

6.5The replacement of the system is the reverse of the previous operations.

6.6It is important to remove and clean the Flue Damper system to ensure the flue ways are clear of soot and debris to ensure the safe and efficient operation of the appliance. The frequency of cleaning will depend on the appliance operating conditions.

6.7The Flue Damper system is designed to give safe and efficient operation of the appliance. Replace any damaged baffles immediately.

6.8Do not modify the Flue Damper.

7. Damper arm adjustment

7.1Set the Damper Arm, Diagram 26

If the damper arm is either too loose or too tight in operation adjust by the following method:

Ensure both pivot bolts are tight

Slacken the two tension bolts

Adjust the adjusting bolt

Re-tighten the two tension bolts