HEARTH DIMENSIONS

SITE REQUIREMENTS

HEARTH DIMENSIONS

The appliance must stand on a constructional hearth with the minimum dimensions as shown in the diagram below.

Check that the building has a suitable loadbearing capacity for the hearth and stove. If in doubt consult a structural engineer for advice before proceeding.

1200mm

 

 

minimum

150mm

 

150mm

minimum

 

minimum

 

 

150mm

 

 

minimum

 

 

Constructional Hearth

Constructional Hearth

 

840mm minimum

840mm minimum

PR7216S

 

 

If you are fitting the appliance into an existing hearth setting check that it complies with the current construction regulations and is at least the minimum sizes shown.

If you have no existing fireplace or chimney, it is possible to construct a suitable non-combustible housing and hearth setting. However, this should be constructed to comply with the requirements of both current national and local regulations with the design approved by your local building control officer. Masonry chimney systems built with clay or concrete liners or pre-fabricated block systems should be constructed in accordance with BS 6461 : Part 1. Factory made insulated systems should comply with BS 4543 : Part 2 and be installed to BS 7566 : Parts 1 to 4.

Remember that any new chimney added to your property may also require planning permission.