MAINTENANCE and SERVICING
Fixing Screw (x10)
Glass (x2)
Glass Seal (3mm)
Fixing Clip (x4)
Door (x2)
8.3Using a screwdriver remove the glass clip fixing screws. The old glass can then be lifted clear of the door. (Note how the 3mm sealing rope is placed between the glass and the door.) Remember to dispose of the old glass safely.
8.4Clean and
8.5Fit a new sealing rope between the new glass and the door, and place the glass into position in the door. Place the glass fixing clips in to position and
8.6Fit only original Stovax ceramic glass, which is suitable to use in high temperature applications.
8.7Using the stove with a damaged door glass could cause dangerous fumes to enter the room, or the stove to overfire, resulting in damage.
9.fitting a new door seal
ALL MODELS
9.1To maintain the safe use of your stove you may need to replace a damaged or worn door sealing rope. To complete this operation, use this method.
9.2Remove the door from the stove, by opening, removing the hinge pins and lifting the door free of the hinge blocks. Then lie the door face down on a soft flat surface, to protect the paintwork and glass.
Seal 14mm
Seal 10mm x 2mm
9.3Remove the old rope and scrape old glue from the locating groove. Clean the locating groove with a clean dry cloth to remove all old dust and debris.
9.4Squeeze a generous bead of fresh Stovax Thermic Seal glue into the rope locating groove. Press the new Stovax rope into the locating groove, placing the joint in the middle of the lower edge of the door.
9.5Refit the door and close the door to apply pressure to the new rope. Leave the stove closed for at least 12 hours before lighting the stove and using at a low output for approximately one day.
9.6Using the stove with a damaged door seal could cause dangerous fumes to enter the room, or the stove to overfire, resulting in damage.