Stovax Stockton Log Effect Stove Range Installation Instructions, Site Requirements, Ventilation

Models: Stockton Log Effect Stove Range

1 27
Download 27 pages 1.75 Kb
Page 12
Image 12
2. VENTILATION

INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

2. VENTILATION

The appliance requires no additional ventilation.

 

3. INSTALLATION OF THE GAS SUPPLY

3.1

Before installation, ensure that the local distribution

 

conditions (identification of the type of gas and pressure)

 

and the adjustment of the appliance are compatible.

3.2

Ensure that the gas supply is capable of delivering the

 

required amounts of gas, and is in accordance with the rules

 

in force.

3.3

Soft copper tubing and soft soldered joints can be used but

 

must not be closer that 50mm (2") to the underside of the

 

firebox.

3.4

A means of isolating the gas supply to the appliance must be

7

PR0846-

AR0522

provided independent of any appliance control.

3.5 All supply gas pipes must be purged of any debris that may

have entered, prior to connection to the appliance.

4. APPLIANCE LOCATION

4.1This fire must stand on a non-combustible hearth that is at least 12mm thick and projects 50mm minimum from the base of the fire in all directions.

*Air-space to non-combustible

*

AR0531

6

AR0604

MINIMUM CLEARANCE

4.2The fire is not suitable for installation agianst a combustible wall. All combustible materials must be removed from behind the fire.

4.3Ensure you comply with all minimum clearance measurements, whether or not to combustible materials.

The above dimensions provide adequate clearance at the side and rear of the fire so that the controls can be reached.

5.TIMBER FRAMED BUILDINGS

5.1It will be necessary to provide additional clearance when the fire passes through a wall containing any combustible materials as so to prevent a fire hazard.

5.2The hole through which the flue will pass, must have a steel sleeve which is positioned so that an air gap of at least 25mm is maintained between the outer surface of the flue, and any part of the sleeve.

5.3For further guidance on the installation of gas appliances in timber framed buildings, contact your local buildings control authority.

NOTE: ATTENTION MUST BE GIVEN TO ALLOWING ADEQUATE CLEARANCE AT THE SIDES AND REAR OF THE STOVE, TO PROVIDE ACCESS FOR SERVICING.