MS-40M — TROUBLESHOOTING (ENGINE/MIXER)
TABLE 3. ENGINE TROUBLESHOOTING (CONTINUED)
SYMPTOM | POSSIBLE PROBLEM | SOLUTION | |
|
|
| |
Insufficient power output | Malfunction in cooling fan? | Check or replace cooling fan. | |
|
| ||
"compression" and overheats | Air | Clean or replace air | |
| |||
|
|
| |
| Over accumulation of exhaust | Clean and check valves. | |
Burns to much fuel | products? | Check muffler, replace if necessary. | |
|
| ||
| Wrong spark plug? | Replace spark plug with manufactures suggested type spark plug. | |
|
|
| |
| Lubricating oil is wrong | Replace lubricating oil with correct viscosity. | |
Exhaust color is continiously | viscosity? | ||
| |||
"WHITE" | Worn rings? | Replace rings | |
| |||
|
|
| |
| Air cleanner clogged? | Clean or replace air cleaner. | |
|
|
| |
| Choke valve has not been set | Adjust choke valve to the correct position. | |
Exhaust color is continiously | to the correct position? |
| |
|
| ||
|
| ||
"BLACK" | Carburetor defective, seal on | Replace carburetor or seal. | |
| carburetor broken? |
| |
|
|
| |
| Poor carburetor adjustment | Adjust carburetor. | |
| "engine runs too rich? |
| |
|
|
|
TABLE 4. MIXER TROUBLESHOOTING
SYMPTOM | POSSIBLE PROBLEM | SOLUTION | |
|
|
| |
| Broken connector pin? | Replace connector pin. Use P/N 963157 when ordering. | |
|
| ||
Blades will not rotate. |
|
| |
| Defective or | Adjust or replace clutch. | |
|
|
| |
Material leaking from drum | Worn or defective paddle shaft | Adjust or replace seals. | |
ends. | seals? | ||
| |||
|
|
| |
| Malfunction in | Clean or replace air filter. | |
| air filter clogged? | ||
|
| ||
|
|
| |
Drum difficult to discharge (tilt) | Defective or worn drum support | Apply grease to bracket or replace. | |
| brackets? |
| |
|
|
| |
| Blades adjusted too tight. | Adjust blades until they almost touch side walls of drum. | |
|
|
|