unit-address = "1"

2.Set the parameters for the ipge devices in the

/kernel/drv/ipge.conf file.

In the following example, the adv_autoneg_cap and adv_1000fdx_cap parameters are set for all Sun PCI-Express Dual Gigabit Ethernet devices. See the driver.conf(4) man page for more information.

adv-autoneg-cap=0 adv-1000fdx-cap=0;

In the following example, the adv-autoneg-capand adv-1000fdx-capparameters are set for a single instance of the ipge device.

name="pciex8086,105f" parent="/pci@7c0/pci@0/pci@2/network@0" unit-address="1" adv-autoneg-cap=0 adv-100hdx-cap=0 adv-100fdx-cap=1 adv-1000fdx-cap=0 adv- 10hdx-cap=0 adv-10fdx-cap=0 adv-1000hdx-cap=0 adv-100T4-cap=0;

Note – If you omit the name=, parent=, and unit-address=definitions, the settings become global to all Sun PCI-Express Dual Gigabit Ethernet instances.

3. Save the ipge.conf file.

Link Partner Parameters

TABLE 3-1describes the read-only link partner capabilities.

TABLE 3-1Read-Only Link Partner Capabilities

Parameter

Description

 

 

 

lp_cap_autoneg

0

= No autonegotiation

 

1

= Autonegotiation

lp_cap_1000fdx

0

= No 1000 Mbit/sec full-duplex transmission

 

1

= 1000 Mbit/sec full-duplex

lp_cap_1000hdx

0

= No 1000 Mbit/sec half-duplex transmission

 

1

= 1000 Mbit/sec half-duplex

lp_cap_100fdx

0

= No 100 Mbit/sec full-duplex transmission

 

1

= 100 Mbit/sec full-duplex

 

 

 

28 Sun PCI-Express Dual Gigabit Ethernet MMF/UTP Adapter Installation and User’s Guide • June 2006

Page 62
Image 62
Sun Microsystems Ethernet MMF/UTP Adapter manual Link Partner Parameters, Set the parameters for the ipge devices