Appendix A System Specifications A-3
A.3 Environmental SpecificationsEnvironmental specifications for the Sun Fire X2250 server areshown in TABLEA-6.
TABLEA-6 Sun Fire X2250 Server EnvironmentalSpecifications
Specification State British Metric
Humidity Operating 7%–93%RH non-
condensing, 80.6˚ F
max wet bulb
7%–93% RH non-
condensing, 38˚ C
max wet bulb
Nonoperating 93% RH, non-
condensing, 100.4˚ F
max wet bulb
93% RH, non-
condensing, 43˚ C
max wet bulb
Vibration Operating 0.12 G x-y,0.17 G z;
5–500 Hz sine
Nonoperating 0.3 G x-y,0.6 G z;
5–500 Hz sine
Shock Operating 4.5G to 3.5 G;
11msec. half-sine
Temperature Operating 36˚F to 100˚ F 2˚ C to 35˚ C
Nonoperating -40˚ F to 154˚ F -40˚ C to 68˚ C
Maximum operating
temperaturederating
-1.8˚ F for every 985
ft. in altitude
-1˚ C for every 300 m
in altitude
Altitude Operating max9,843 ft max 3,000 m