Chapter 4 Maintaining the Sun Fire X2250 Server 4-13
4. Check the routing of all cables for obstructions, and then reinstall the cover as
described in Section 4.3, “Powering Offthe Server and Removing the Cover” on
page4-3.
4.5.3 Replacing a Hard Disk Drive and CarrierThe following procedures describe how to remove and replacea hard disk drive
(HDD) and carrier.
4.5.3.1 Removing an HDD and Carrier
Toremove the HDD and carrier:
1. If you are not using an integrated-mirroring (IM) configuration,you must power
off the server before removing an HDD; it is not necessary to remove the cover.
Power off the system as described in Section4.3, “Powering Off the Server and
Removing the Cover” on page 4-3.
If you are using an IM configuration, start with Step2.
2. Squeeze the release latch on the HDD and carefully swing the arm to the left as
far as it will go.
FIGURE4-11 Removing a Hard Disk Drive