3-2 Sun Fire X2250 Server Service Manual • April 2009
3.1 Pc-Check Diagnostics Overview
Sun Fire X2250 server diagnostics are contained in the DOS-based Pc-Check utility.
This program can be accessed and executed only from the Sun Fire X2250 Server
Tools& Drivers CD. Pc-Check was designed to detect and test all motherboard
components, ports, and slots.
Ifyou encounter anyhardware-related error message (such as memory errors or hard
disk errors) on your Sun Fire X2250 server,run one of the following:
Advanced Diagnostics Test:A specific hardware component test
Immediate Burn-in Test:A Sun Fire X2250 server diagnostic test script
The following proceduredescribes how to access these test options from the Sun Fire
X2250 Server Tools& Drivers CD.

3.1.1 Accessing the Pc-Check Diagnostics Software

1. Do one of the following, depending on which method you are using to access
the Pc-Check diagnostics software:
If your server has a DVD drive installed: Insert the Sun Fire X2250 Server Tools&
Drivers CD into your DVD drive and reboot the system.
If you are running the Pc-Check softwarefrom a PXE server: Follow the instructions in
Appendix B to set up the PXE server.
The system boots to the Sun Fire X2250 Server Tools& Drivers CD main menu.
2. Type 1to run the hardware diagnostics software.
The system information loads, the Diagnostics main menu opens, and the
following menu options are displayed:
System Information Menu
Advanced Diagnostics Tests
Immediate Burn-in Testing
Deferred Burn-in Testing
Create Diagnostic Partition
Show Results Summary
Print Results Report
About PC-CHECK
Exit to DOS