Workaround: None
SIA will not install FEM drivers for Windows 2003
Change Request ID: 6769562
If SIA is used to install Windows 2003 on a system that contains the model x1029 A FEM, the associated device will be highlighted with a yellow question mark in the Windows Device Manager, indicating that the drivers are not installed correctly.
Workaround: None
RHEL installed using SIA reports a MPT Fusion ctl drivers error
Change Request ID: 6737853
If SIA is used to install RHEL 4.6 on a system that does not contain a Sun Blade I/O Expansion Module II (mptsas) controller, the following error will occur when RHEL boots:
starting MPT Fusion ctl drivers FAILED
This error is harmless and can be ignored.
Workaround: None
This issue will be fixed in future software release.
SIA displays ILOM version as Unknown
Change Request ID: 6878691
When installing the Linux operating system using SIA version 2.3.8, the ILOM version is displayed as “Unknown” in the System Information screen.
This issue will be fixed in future software release.
SIA displays incorrect chassis information
Change Request ID: 6878692
Sun Blade X6440 Server Module Product Notes | 11 |