SAFETY

16.To prevent electric shock, do not use this polarized plug with an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure.

Pour préevenir les chocs électriques ne pas utiliser cette fiche polariseé avec un prolongateur, un prise de courant ou une autre sortie de courant, sauf si les lames peuvent être insérées à fond sans laisser aucune parIVe à décou- vert.

17.Grounding or Polarization — Precautions should be taken so that the grounding or polarization means of the Component is not defeated.

This apparatus does not exceed the Class A/Class B (which- ever is applicable) limits for radio noise emissions from digital apparatus as set out in the radio interference regulations of the Canadian Department of Communications.

ATTENTION — Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant las limites applicables aux appareils numériques de class A/de class B (selon le cas) prescrites dans le règlement sur le brouillage radioé- lectrique édicté par les ministere des communications du Canada.

WARNING – TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO

NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

CAUTION: TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF

PLUG TO WIDE SLOT, FULLY INSERT.

ATTENTION: POUR ÉVITER LES CHOCS ÉLECTRIQUES, INTRO- DU-

IRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRE-

SPONDANTE DE LA PRISE ET POUSSER JUSQU’AU FOND.

EXAMPLE OF ANTENNA GROUNDING ACCORDING TO NATIONAL ELECTRICAL CODE INSTRUCTIONS CONTAINED IN ARTICLE 810–“RADIO AND TELEVISION EQUIPMENT”

GROUND CLAMP

 

ANTENNA

 

LEAD IN WIRE

GROUND CLAMPS

 

 

ANTENNA DISCHARGE UNIT

 

(NEC SECTION 810-20)

 

GROUNDING

SERVICE

CONDUCTORS

(NEC SECTION 810-21)

ENTRANCE

 

EQUIPMENT

 

GROUND CLAMPS

 

 

POWER SERVICE GROUNDING

 

ELECTRODE SYSTEM

 

(NEC ART 250, PART H)

NEC NATIONAL ELECTRICAL CODE.

NOTE TO CATV INSTALLER

This reminder is to call the CATV system installer's attention to Article 820-40 of the NEC that provides guide- lines for proper grounding and in particular, specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical.

OUTSIDE ANTENNA GROUNDING

If an outside antenna is connected to the receiver, be sure the antenna system is grounded so as to provide some protection against voltage surges and built-up static charges. Article 810 of the National Electrical Code, ANSI/NFPA 70, provides information with regard to proper grounding of the lead-in wire to an antenna-discharge unit, connection to grounding electrodes, and requirements for the grounding electrode. See Figure above.

2

User’s Manual

Page 4
Image 4
Sunfire TGM-100C user manual User’s Manual

TGM-100C, TGM-100 specifications

The Sunfire TGM-100 and TGM-100C are advanced, next-generation gasification systems developed by Sunfire, a pioneer in sustainable energy technologies. These models are designed to convert a broad range of carbon-based feedstocks, such as biomass and waste materials, into high-quality synthesis gas (syngas). Utilizing a unique combination of innovative technologies, they stand out in the realm of clean energy production.

One of the main features of the TGM-100 and TGM-100C is their efficient conversion process. They employ a dual-stage gasification technology that enhances the efficiency of energy extraction from various raw materials. The first stage utilizes pyrolysis, where the feedstock is thermally decomposed in the absence of oxygen, leading to the production of bio-oil and char. This is followed by a gasification stage, where the remaining solid residues are converted into syngas using controlled amounts of oxygen and steam. This two-step process ensures high conversion rates and maximizes energy output.

In terms of technology, both models are equipped with advanced control systems that monitor and optimize the gasification parameters in real-time. These systems improve operational flexibility and reliability, allowing the units to adapt to varying feedstock qualities. Additionally, the TGM-100C version is designed with modular capabilities, making it easier to scale projects according to specific energy needs or feedstock availability.

Another characteristic that sets these models apart is their emphasis on environmental sustainability. The systems are designed to minimize emissions, contributing to a cleaner energy landscape. The syngas produced can be utilized in various applications, including power generation, chemical production, and as a substitute for natural gas in industrial processes.

The TGM-100 and TGM-100C are also notable for their robustness and durability. Built to withstand high operational demands, they feature high-grade materials and components that ensure long-lasting performance even under challenging conditions. These characteristics make them suitable for a range of applications, from industrial settings to remote off-grid locations.

In summary, the Sunfire TGM-100 and TGM-100C represent cutting-edge advancements in gasification technology. With their efficient energy conversion processes, modular capabilities, real-time optimization, and commitment to sustainability, they are a compelling choice for those seeking reliable and environmentally friendly energy solutions.