Operation ñ Mechanical Models

Setting the Temperature

Turn the THERMOSTAT to regulate the temperature you desire: range 64˚F to 90˚F.

Setting the Timer

Set the TIMER to the desired operating time (1 to 8 hours).

When the set time has elapsed, the machine will shut off automatically.

Regulating the Airflow Direction

Turn the roller on the air vent to control the airflow direction from the vertical louvers.

NOTICE!

The compressor will start approximately 3 minutes after the unit is turned on (this will help prolong the life of the compressor). After switching the unit off, please wait at least 3 minutes before turning the unit back on.

The cooling system will switch off if the room temperature is lower than set. The fan, however, keeps working at the set level. If the ambient temperature rises above the chosen level, the cooling will resume.

11

Before Use

Important!

Transport the unit in an upright position only, or leave it in an upright position for at least 2 hours before first use.

Always place the unit on an even surface (Figure 1).

Make sure the unit is connected to a correctly grounded power supply (refer to the rating label located at the back of the unit).

An opening in a window or wall is required to accommodate the exhaust hose (kit supplied) to expel the warm air.

Do not cover or obstruct the appliance inlet or outlet grilles (Figure 2).

To avoid the risk of shock, the product should never be used in bathrooms, shower rooms or in any other steamy or wet areas.

The unit will cool when the room temperature is between 64˚F and 110˚F depending on the thermostat setting.

Do not sit or place objects on the unit.

Do not touch the unit with wet/damp hands or when standing barefoot.

Avoid all contact with chemical based materials.

The filter must be used with the product at all times. When removing for cleaning, always disconnect the unit from the mains first.

Turn off the appliance when not in use.

At the end of each season all water must be drained and the unit and filters cleaned before storage.

Drainage of the water container is required before moving the unit or putting it into storage.

If the electric socket is different from the plug provided, have a professionally qualified electrician replace the plug with a suitable one. Avoid the use of adaptor plugs, multiple sockets and/or extension leads; if their use is necessary, ensure that they conform to the current safety regulations.

Do not pull the supply cable or place it near a source of heat; always unroll it completely to avoid the possibility of dangerous overheating.

If the supply cord is damaged, it must be replaced by the service agent or a similarly qualified person.

THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.

4

Fig. 1

Fig. 2

Page 3
Image 3
Sunpentown Intl WA-1230H, WA-1010E Operation ñ Mechanical Models, Before Use, Setting the Temperature, Setting the Timer

WA-1010E, WA-1230E, WA-1230H specifications

Sunpentown International offers a range of multifunctional and highly efficient air conditioners, with models like the WA-1230E, WA-1230H, and WA-1010E gaining significant popularity among consumers. These units are designed to offer comfort and convenience in a variety of settings, from homes to offices, thanks to their portability and advanced technology.

The WA-1230E is a powerful model that features a cooling capacity of 12,000 BTUs, making it suitable for medium to large-sized rooms. One of its main features is the energy-saving mode that allows users to reduce electricity consumption without sacrificing cooling performance. It is equipped with a digital display for easy temperature adjustment and has a built-in dehumidifier function, which helps to maintain a comfortable humidity level in the room.

In contrast, the WA-1230H is perfect for users seeking both cooling and heating solutions. This model also boasts a 12,000 BTU cooling capacity and features a heat pump function, enabling it to operate efficiently during colder months. The WA-1230H comes with a remote control, allowing for convenient operation from anywhere in the room, and an adjustable thermostat for precise temperature management. Additionally, its quiet operation makes it ideal for nighttime use or quiet environments.

The WA-1010E is another remarkable model, featuring a slightly smaller cooling capacity of 10,000 BTUs. This makes it the perfect option for smaller spaces or individual rooms. The WA-1010E offers similar functionalities, including an energy-saving mode, digital display, and dehumidification capabilities. Its compact design makes it easy to move from room to room, catering to varied cooling needs throughout the day.

All three models are designed with user-friendly features such as easy-to-use controls, an integrated fan, and various speed settings to suit individual preferences. Moreover, their portable design eliminates the need for complicated installation, which is a significant advantage for consumers who wish to avoid the hassle of traditional window units.

Overall, Sunpentown International’s WA-1230E, WA-1230H, and WA-1010E air conditioners stand out in the market, thanks to their innovative technologies, versatility, and energy efficiency. With these models, users can maintain optimal indoor temperatures comfortably and conveniently year-round.