Sunpentown Intl WA-1010E Specifications, Drainage, Model Number, WA-1010H, WA-1010M, 63 lbs

Models: WA-1010E WA-1230E WA-1230H

1 9
Download 9 pages 30.2 Kb
Page 7
Image 7
Specifications

Specifications

Model Number

WA-1010E

WA-1010H

 

WA-1010M

 

 

 

 

Cooling Capacity

10,000BTU/hr

10,000BTU/hr

 

 

 

Heating Capacity (1)(2)

N/A

10,000BTU/hr

Drainage

During the process of cooling or heating, some water will be extracted from the air into the unit. Most of this water is used to cool the unit and make it run more efficiently. This is a feature not found in most Portable Air Conditioners. If the unit is operated in VERY HUMID air, water will collect in the container inside the unit. If the water container is full, the compressor and fan will stop. The POWER indicator will blink to inform you to empty the

internal container. To make the cooling function work again, please empty the water by one of the following methods:

Power Consumption

660W / 6.3A

660W / 6.3A

 

 

 

Humidity Removal Capacity

50 pts./day

50 pts./day

 

 

 

Recommended Room Size*

300 sq. ft.

300 sq. ft.

 

 

 

Power Supply

120V / 60H z / 1 Phase

120V / 60H z / 1 Phase

 

 

 

Compressor

Rotary

Rotary

 

 

 

Refrigerant

R-22

R-22

 

 

 

Fan Speed

2

2

 

 

 

Timer

WA-1010E: 1-12hours

1-12 hours

 

WA-1010M: 1-8hours

 

 

 

 

 

 

Thermostat

64°F - 90°F

64° F - 90°F

 

 

 

Net Weight

63 lbs

66 lbs

Dimensions

17"W x 17"D x 30"H

17"W x 17"D x 30"H

 

 

 

Working Temperature

Cooling: 64°F to 110°F

Cooling: 64°F to 110°F

 

 

Heating: 41°F to 81°F

REMARKS:

1. The data may vary, please refer to the rating label on the back on the back of the unit.

2. The above conditions are measured at: Cooling - Indoor: RT 81°F, RH 60% Heating - Indoor: RT 68°F, RH 60%

* Uninsulated rooms such as sunrooms, garages, or attics should be less than 300 sq. ft.

By the Draining into a Container

Use a Shallow Container or Dish

1.Turn off the unit.

2.Position a flat container or dish under the drain hole.

Do not allow the water to drip continuously into the container, as it might easily overflow.

3.Remove the drain knob & rubber plug from the drain hole. The condensed water will drain out automatically.

4.When the container is almost full, replace the rubber plug into the drain hole to stop the water. Empty the container.

5.Repeat steps 2, 3 & 4 until all the condensed water is emptied.

6.Once all the condensed water has been removed, replace the rubber plug into the drain hole firmly. The Full Water indicator should be off now.

7.Replace the drain knob.

*Do not allow the water to drip continuously into the tray, as it may easily overflow.

By Water Tube (Continuous Drainage)

1.Remove the drain knob and rubber plug and keep them for future use.

2.Use Teflon tape to cover threading on spout, making a flat surface for the hose. This will prevent leakage.

3.Connect a suitable water tube (of 3/4" internal diameter - supplied) to the water hole. The condensed water will drain out automatically.

4.If you want to extend the water tube you can connect it with another tube (outside diameter ¾”).

Special Caution for Heating Function!

1.Install the exhaust pipe securely in order to exhaust the cool air to the outside (please see page 6).

2.You can use the continuous drainage option as described above.

3.The warmer the outside air the more heat will be pumped into the room. Working range for heat pump function is 41°F to 81°F. When used in room temperatures outside this range the unit may not function properly.

4.While using the heating function during low temperatures, sometimes the heating will stop for a while in order to melt the internal frost. When this occurs, just wait for heating to resume. This is normal for compressor operated devices.

Water Hole

Rubber Plug

Drain Knob

Rubber Plug

Drain Knob

Drain Pipe

Original Water Tube

Model NumberWA-1010E Extended Water Tube WA-1010HWA-1010M(OD: 3/4")

2

12

Page 7
Image 7
Sunpentown Intl WA-1010E, WA-1230H, WA-1230E Specifications, Drainage, Model Number, WA-1010H, WA-1010M, 63 lbs, 66 lbs