Sunpentown Intl WA-1010E Operation - Electronic Control Models, Installation, Mounting the unit

Models: WA-1010E WA-1230E WA-1230H

1 9
Download 9 pages 30.2 Kb
Page 4
Image 4
Operation - Electronic Control Models

Operation - Electronic Control Models

Setting The Fan Speed

Press the SPEED button to choose the fan speed you require, high or low.

The indicator of high or low fan will light up at the same time.

If the unit is in AUTO mode, it will select the fan speed automatically according to the ambient temperature (the related indicators, cool, fan or heat will light up), at this time the fan speed switch is invalid.

Setting the Timer

Press the TIMER button to set the operating hours you desire (1 to 12 hours, the timer indicator will light up). When the set time has elapsed, the machine will turn off automatically. The display window will show the hour(s) you set as you press the TIMER button. If the timer button is not pressed, the unit will work continuously.

By pressing the timer button but without turning on the unit, you

can PRE-SET the time for the machine to work. For example, if you press the timer to ‘2’, the unit will come on automatically after 2 hours. All the above functions can also be performed with the supplied remote

control. This remote control requires 2 AAA batteries to operate.

Regulating the airflow direction

Turn the roller on the air vent to control the airflow direction from the vertical louvers.

Notice!

To prolong the unit’s life, it will start 3 minutes after the unit was switched on. After switching off, please wait at least 3 minutes before switching it on again.

The cooling system will switch off if the room temperature is lower than set. The fan, however, keeps working at the set level. If the ambient temperature rises above the chosen temperature +5˚F, the cooling will resume.

In heating mode, the compressor will switch off if the room temperature is HIGHER than the set one (The fan keeps working at the set level). As the room

temperature drops below the selected level –5˚F, the heating will resume.

This machine is equipped with an ANTI-FROST function. While using the heating function during low temperatures, sometimes the heating will stop for a while in order to melt the internal frost. When this occurs just wait for heating to resume.

As you switch on the heating, the fan will stop for 15-20 seconds first for warm up purposes.

9

Installation

Mounting the unit

This unit is a portable air conditioner. It can be moved from room to room so that the cooling can follow you anywhere. Fitting the exhaust hose is easy, through a window or wall. Please refer to either of the following ways:

1. Using the foam strips

Connect the supplied foam strips with the exhaust pipe, let the hot air flow to the outside.

Should the foam strip(s) be too large, cut off the extra part to fit the window.

2. Using the Through the Wall

Make a hole (5" in diameter) in the wall to fit the supplied round connector.

Fit the hose directly to the round connector.

When the hole is not in use, use the cap for the round connector to cover the hole.