R e q u i r e m e n t s
12" (300mm)
0.10" (2.6mm)

4

REQUIREMENTSJoistsSheet rockWallSupportingStructureLedgeof TubManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundR e q u i r e m e n t s Manual backgroundManual background

REQUIREMENTS

Failure to meet requirements listed below could result in serious bodily harm.

Ceiling Requirements

Install to a rigid ceiling (must have a framework above it).

Must have a maximum of 24" (610mm) between the trusses in the ceiling.

Ceiling must be made of wood or 1/2"(12.7mm) sheet rock or thicker.

Ensure ceiling and floor are clear of any dust, grease, water or any foreign substance.

24" max

Joists

1/2" min.

Sheet rock

Joists

Suspended wire or rods

Sheet rock or tile

A build-up of nicotine, grease or water on the ceiling will affect the integrity of the Easytrack System.

• Installing a post directly under a joist or truss is not required, but preferable.

Floor Requirements

Ensure flooring meets local building code standards. (Termites or water damage may affect the structure of the floor).

Ensure floor is clear of any dust, grease, water or any foreign substance.

Floor must not have a slope of more than 0.5 °. See drawing below to determine the floor slope. Use a level or contact a contractor if unsure of floor slope.

Bath Requirements

X

Y

24" (600mm)

36" (900mm)

48" (1200mm)

0.21" (5.2mm)

0.31" (7.9mm)

0.42" (10.5mm)

 

 

 

• Ensure your tub is made of porcelain or

 

 

 

Wall

metal and has sufficient structure

 

 

 

 

 

Supporting

 

underneath the tub to withstand the

3"

 

1.5" min

 

Structure

weight required (see drawing below).

 

 

(75mm)

 

 

 

If you are unsure of the structural

 

 

 

 

 

 

 

integrity of the tub, contact the manu-

 

 

 

 

facturer or a contractor to evaluate the

 

Ledge

 

 

structure.

 

of Tub

 

53" – 65"

• Ensure you have 3" of ledge space

 

 

 

(1350 – 1650mm)

available on each end of the tub (see

 

 

 

 

drawing). The round "foot" on the bath base must entirely be in contact with the tub ledge.

The tub length must be between 53”–65” (1350-1650 mm).

Any protrusion from the wall next to the tub must be removed to provide space for the post.

A molded plastic tub with a protruding wall may obstruct the post or base if there is not a straight line between the corners of the tub.

Tub must be clean of any soap or dust and must be dry before placing the tub base onto the tub. DO NOT ATTEMPT TO INSTALL THE BATH BASE WITHOUT THOROUGHLY CLEANING AND DRYING THE SURFACE OF THE TUB.

Floor beneath the tub must be according to local building code standards. (Water damage or termites may affects the integrity of the floor or wall structure.)

If you have any doubt with respect to the ceiling or bath structure, consider installing the Easytrack System with a wall mount. The wall mount must be installed by a licensed contractor.

Ensure posts are straight using the level provided; failure to do so may cause injury.

Every month a maintenance check should be done to ensure all posts are level. (See "Maintenance" section in this manual).

Make sure the padded surface of the top plate and foot plate are kept clean and are intact.

Protect the Easytrack System and its accessories during transport.