1
104
122
122
Download
122 pages
59.88 Kb
101
102
103
104
105
106
107
108
Install
Alarm Reset JAR
Password
POST Errors
Latency Timer
Onboard Indicators
Connecting Data Cables
Reset Button
Accessing the drive bays
Preparing for Setup
Page 104
Image 104
S
UPER
S
ERVER
6025B-UR
User's Manual
Notes
B-6
Page 103
Page 105
Page 104
Image 104
Page 103
Page 105
Contents
1.0b
SUPER
SUPERSERVER 6025B-UR
USER’S MANUAL
Manual Revision 1.0b Release Date June 6
Printed in the United States of America
Chapter 2 Server Installation
Chapter 4 System Safety
Preface
About This Manual
Chapter 5 Advanced Serverboard Setup
Chapter 6 Advanced Chassis Setup
Chapter 7 BIOS
Appendix A BIOS POST Messages Appendix B BIOS POST Codes
Preface
Table of Contents
Chapter 2 Server Installation
Chapter 4 System Safety
Chapter 5 Advanced Serverboard Setup
Connecting Data Cables
Chapter 6 Advanced Chassis Setup
Chapter 7 BIOS
Appendix C Software Installation Appendix D System Specifi cations
Appendices
Appendix A BIOS POST Messages Appendix B BIOS POST Codes
SUPERSERVER 6025B-UR Users Manual
Chapter Introduction
1-1 Overview
1-2 Serverboard Features
Processors
Memory
Serial ATA
Figure 1-1. Intel 5000P/ESB2 Chipset System Block Diagram
Other Features
ATI Graphics Controller
1-3 Server Chassis Features
System Power
Serial ATA Subsystem
PCI Expansion Slots
I/O Backplane
Cooling System
1-4 Contacting Supermicro
Headquarters
Europe
Asia-Pacific
Chapter Server Installation
2-3 Preparing for Setup
2-1 Overview
2-2 Unpacking the System
Warnings and Precautions
Choosing a Setup Location
Rack Precautions
Server Precautions
Rack Mounting Considerations
Ambient Operating Temperature
Reduced Airflow
Mechanical Loading
Identifying the Sections of the Rack Rails
2-4 Installing the System into a Rack
Installing the Chassis Rails
Figure 2-1. Installing Chassis Rails
Installing the Server into a Telco Rack
Installing the Rack Rails
Installing the Server into the Rack
Figure 2-2. Installing the Server into a Rack
2-5 Checking the Serverboard Setup
1. Accessing the inside of the System see Figure
4. Installing add-on cards
2. Check the CPUs processors
Figure 2-3. Accessing the Inside of the System
2-6 Checking the Drive Bay Setup
1. Accessing the drive bays
5. Supplying power to the system
2. DVD-ROM and floppy disk drives
3-2 Control Panel Buttons
Chapter System Interface
3-1 Overview
3-3 Control Panel LEDs
3-4 Drive Carrier LEDs
SAS/SATA Drives
SUPERSERVER 6025B-UR Users Manual
Chapter System Safety
4-1 Electrical Safety Precautions
4-2 General Safety Precautions
4-3 ESD Precautions
BATTERY HOLDER
4-4 Operating Precautions
Figure 4-1. Installing the Onboard Battery
Chapter Advanced Serverboard Setup
Precautions
5-1 Handling the Serverboard
Unpacking
5-2 Processor and Heatsink Installation
Installing the Processor
CPU installed in socket PnP cap released from load plate
Gold dot Socket key CPU key Notched corner CPU pin Load lever
Installing the Heatsink
Removing the Heatsink
Connecting Power Cables
5-3 Connecting Cables
Connecting Data Cables
Connecting the Control Panel
Figure 5-1. Front Control Panel Header Pins JF1
5-5 Installing Memory
DIMM Installation See Figure
5-4 I/O Ports
Figure 5-2. Rear Panel I/O Ports
Possible System Memory Allocation & Availability
5-6 Adding PCI Cards
Figure 5-3. Installing DIMM into Slot
2. PCI card installation
1. PCI Expansion Slots
5-7 Serverboard Details
Figure 5-4. SUPER X7DBU Layout
SUPER X7DBU
North Bridge 5000P
Default Setting
Connector
X7DBU Quick Reference
Jumper
5-8 Connector Definitions
ATX Power Connector
Auxiliary Power Connector
Processor Power Connector
Overheat/Fan Fail/Power Fail/UID LED
HDD LED
NIC1 LED
NIC2 LED
Power Fail LED
Reset Button
Power Button
Universal Serial Bus USB0/1
Universal Serial Bus Headers
Serial Ports
Fan Headers
Universal Serial Bus Headers Pin Definitions USB2, USB3, USB4
Power LED/Speaker
Chassis Intrusion
ATX PS/2 Keyboard and PS/2 Mouse Ports
Overheat LED
Wake-On-LAN
Wake-On-Ring
SMBUSPS
Wake-On-LAN Pin Definitions JWOL
Alarm Reset JAR
LAN1/2 Ethernet Ports
SGPIO
Alarm Reset Pin Definitions JAR
5-9 Jumper Settings
VGA Enable/Disable
Explanation of Jumpers
CMOS Clear
LAN Enable/Disable
Watch Dog Enable/Disable
I2C Enable/Disable
LAN Enable/Disable Jumper Settings JPL1, JPL2
5-10 Onboard Indicators
LAN1/LAN2 LEDs
Floppy Connector
5-11 Floppy, IDE and SATA Drive Connections
IDE Connector
SATA Ports
IDE Drive Connector Pin Definitions IDE#1
SATA Port Pin Definitions SATA0 ~ SATA5
SUPERSERVER 6025B-UR Users Manual
Chapter Advanced Chassis Setup
6-1 Static-Sensitive Devices
Unpacking
Tools Required
6-2 Control Panel
Figure 6-1. Front and Rear Chassis Views
6-3 System Fans
System Fan Failure
Replacing System Fans
2. Installing a new fan
Figure 6-2. Removing System Cooling Fans
6-4 Drive Bay Installation/Removal
Accessing the Drive Bays
Figure 6-3. Mounting a SAS/SATA Drive in a Carrier
SAS/SATA Drive Installation
1. Mounting a SAS/SATA drive in a drive carrier
2. Installing/removing hot-swap SAS/SATA drives
Figure 6-4. Removing a SAS/SATA Drive Carrier
Removing the Air Shroud
DVD-ROM and Floppy Drive Installation
Hard Drive Backplane
6-5 Power Supply
Power Supply Failure
Removing/Replacing the Power Supply
1. Removing the power supply
Chapter BIOS
System BIOS
How To Change the Configuration Data
Starting the Setup Utility
7-2 Running Setup
7-3 Main BIOS Setup
Default settings are in bold text unless otherwise noted
Press the Delete key to enter Setup
Main BIOS Setup Menu Main Setup Features
BIOS Date
System Time
System Date
IDE Channel 0 Master/Slave and Secondary IDE Master/Slave
Type
Multi-Sector Transfers
LBA Mode Control
32 Bit I/O
Transfer Mode
Serial ATA SATA RAID Enable
Parallel ATA
Native Mode Operation
SATA Controller Mode
7-4 Advanced Setup
Boot Features
QuickBoot Mode
QuietBoot Mode
Power Button Behavior
Power Loss Control
Memory Cache Cache System BIOS Area
Cache Video BIOS Area
Default Primary Video Adapter
Cache Base 512K-640K
Cache Extended Memory
Discrete MTRR Allocation
Emulated IRQ Solutions
PCI Parity Error Forwarding
Reset Configuration Data
PCI-Exp. I/O Performance
Enable Master
Latency Timer
Large Disk Access Mode
SERR Signal Condition
Crystal Beach Features
Clock Spectrum Feature
Branch 1 Rank Interleaving & Sparing
Enhanced x8 Detection
Enabling Multi-Media Timer
USB Function
Legacy USB Support
Advanced Processor Options
Intel R Virtualization Technology Available when supported by the CPU
Intel EIST Support Available when supported by the CPU
I/O Device Configuration
KBC Clock Input
Interrupt
Serial Port B
Mode
Floppy Disk Controller
DMI Event Logging
Event Log Validity
Event Log Capacity
View DMI Event Log
Console Redirection
COM Port Address
BAUD Rate
Console Type
Hardware Monitor Logic
CPU Temperature Threshold
Voltage Monitoring
CPU1 Temperature CPU1 Second Core Temperature CPU2 Temperature
Temperature Monitoring Available if supported by the CPU
CPU1 Temperature/CPU1 Second Core CPU2 Temperature/CPU2 Second Core
PECI Agent 1 Temperature PECI Agent 2 Temperature
PECI Agent 3 Temperature PECI Agent 4 Temperature System Temperature
System Event Logging
Clear System Event Logging
Existing Event Log Number
Event Log Control
OS Boot Watch Dog
Timer for Loading OS Minutes
Time Out Option
System Event Log/System Event Log List Mode
Realtime Sensor Data
Supervisor Password Is
User Password Is
Set Supervisor Password
Set User Password
Boot Priority Order/Excluded from Boot Orders
7-6 Boot
Password on Boot
Load Setup Defaults
7-7 Exit
Exit Saving Changes
Exit Discarding Changes
SUPERSERVER 6025B-UR Users Manual
Appendix A BIOS POST Messages
Keyboard error
Keyboard locked - Unlock key switch
Monitor type does not match CMOS - Run SETUP
System CMOS checksum bad - Default configuration used
System timer error
Real time clock error
Check date and time settings
System cache error - Cache disabled
Fail-Safe Timer NMI Failed
Allocation Error for device
Entering SETUP
PS/2 Mouse Boot Summary Screen
Fixed Disk n
Invalid System Configuration Data
I/O device IRQ conflict
Press F1 to resume, F2 to Setup, F3 for previous
Press F2 to enter Setup
System BIOS shadowed
Video BIOS shadowed
SUPERSERVER 6025B-UR Users Manual
Appendix B BIOS POST Codes
Recoverable POST Errors
Terminal POST Errors
POST Code
8254 timer initialization
Test RAM between 512 and 640 kB
Check for SMART Drive optional
The following are for boot block in Flash ROM
SUPERSERVER 6025B-UR Users Manual
Appendix C Software Installation
C-1 Introduction
Important Notes
Serial ATA SATA
Intel Matrix Storage
Configuring BIOS for SATA RAID Functions Native Mode
RAID Configurations
Using the Intel ESB2 SATA RAID Utility Program
1. Creating, Deleting and Resetting RAID Volumes
Creating a RAID 0 Volume
Creating a RAID 1 Volume
Creating a RAID 10 RAID 1+ RAID
Creating a RAID 5 Set Parity
Deleting a RAID Volume
Resetting to Non-RAID and Resetting a RAID HDD
Exiting the Intel Matrix Storage Manager Utility
C-2 Installing Windows XP/2000/2003 for RAID Systems
New Operating System-Windows XP/2000/2003 Installation
C-11
C-3 Installing the Operating System and other Software Programs
Driver/Tool Installation Display Screen
Supero Doctor III Interface Display Screen-I Health Information
Supero Doctor
C-12
Supero Doctor III Interface Display Screen-II Remote Control
C-13
C-14
BIOS
Appendix D System Specifications
Chipset
Memory Capacity
Weight
Power Supply
Serverboard
Chassis
Regulatory Compliance
SUPERSERVER 6025B-UR Users Manual
Top
Page
Image
Contents