4.12 Channel Power switch (SX-ST series only)
It powers ON or OFF the entire input module. This function is useful to save the battery power when only a few numbers of channels are being used. An audible pop will be introduced in the mixer's outputs if this switch is used during normal operation.
4.13 PFL/AFL push button
The P/A push button is used to monitor the channel signal
NOTES:
-you can still monitor the PFL signal even if the channel is turned OFF ( Muted )
-Jumper S12 (L) and S13(R) determine whether the AFL is taken Pre or Post PAN pot
4.13.1 P/A LED
The P/A LED lights ON to indicate when the PFL/AFL push button is depressed. This LED is blinking to warn you when the SOLO Mode is selected.
4.14VCA's Group Selector(SX-VT Series with VCA input module only)
The
Thus, the channel fader do not control the audio modulation but, instead, a DC voltage that controls the VCA circuitry.
This technology offers the possibility to build up an optional VCA grouping system of up to 8 independent groups.
A VCA Group allows to use just one fader to control the global mix level of a large group of channels ( such as drums, horns, backing vocals, etc.) and thus, providing an easier global control of that particular mix group.
The VCA Group Selector assigns the channel to one of the 8 VCA Groups. Each group is then controlled by a Master Group Fader located on a Master Fader Module by means of a DC voltage.
NOTE: when position "0" or "9" is selected, the channel is disconnected from the VCA grouping system
4.15Compressor (SX-VT series with VCA input module only)
This switch enables or disables the channel compressor. The compressor is used to limit the dynamic range of the modulation. In case of extreme amplitudes or signal peaks, heavy distortion may occur, especially with digital recording equipment. To avoid this kind of distortion or, for example, to avoid loudspeakers getting damaged by overload, use the compressor. Compressors can also be used to change the sound of an instrument by applying extreme settings. The principle function used in these devices is dependent on an automatic gain control which reduces the amplitude of loud passages and therefore restricts the original dynamics to a desired range.
4.15.1 Threshold
This control sets the threshold level for the compressor. It has a range of
4.15.2 Ratio
It controls the compression ratio between the input and output levels for all signals exceeding the threshold point. The control range can be adjusted with the RATIO knob from a 1:1 ratio to an infinity:1 ratio.
4.15.3 Compressor LED
This Led will light ON only when the compressor becomes active and turns OFF when the compressor is inactive, depending if the signal level is equal to or higher than the threshold point.
page 16 |