7.6 Monitoring

The SONOSAX SX-ST and SX-VT offers 3 identical and independent stereo Monitoring sections.

The left most Monitor section (the Main Monitor) is dedicated to the sound engineer working on the mixer. The upper rotary switch selects the source for the phone output, the monitor output and the peak-meters. As soon as a PFL/AFL button is depressed, the monitor outputs and the modulo-meters automatically switch over from the monitor source to the selected P/A.

The lower rotary switch changes the listening mode ( mono –stereo – M/S ) of the selected source.

The two additional middle and right most monitor sections are available for independent remote monitoring and communication purposes, both having an separate communication system ( Private Lines ). They can be used to return different monitoring selections to e.g. the boom operator and the director/producer while on location recording, or to a speaker cabin and to the video control room in broadcasting applications.

7.6.1 Monitor Source Selector

The upper three rotary switches select the source to be monitored:

1-2 to 7-8 : select Master Groups per pair 1 (Left) – 2 (Right) / 3 (Left) – 4 (Right) etc

AUX 1-2 : select Aux Sends 1 (Left) and 2 (Right)

AUX 3-4 : select Aux Sends 3 (Left) and 2 (Right)

7.6.2 Monitor Mode selector

The lower three rotary switches define the listening mode of the selected source:

RET :

monitors the after fader stereo mix of the 8 Return tracks

ODD :

the odd channel only of the selected stereo source is monitored in Mono

EVEN :

the even channel only of the selected stereo source is monitored in Mono

ST :

the selected source is monitored in stereo

M :

the selected stereo source is summed in Mono to easily check the Mono compatibility and

 

to detect phase errors

MS:

decode a MS signal for monitoring purposes.

The decoder is for monitoring purpose only and does not affect the main. The M-(left) channel is applied to both L & R channels in phase and the S-(right) channel is applied in phase to the left channel and out of phase to the right channel. The M/S decoder has a fixed ratio of 50%

NOTE: in Odd, Even and Mono modes, the signal is monitored in mono on both left and right sides.

7.6.3 Phones Level 1 to 3

Set the level of the corresponding monitor output (1 to 3) from - infinite (Mute) to +15 dBu

7.7 Communication and Private Lines

The SX-ST / SX-VT offers three independent communication systems: a main COM for general purposes and 2 full duplex Private Lines used for communication within the 2nd and 3rd monitoring sections.

COM : talk to all communications lines, incl. PL and PL2

PL1 : talk to second monitor section

PL2 : talk to third monitor section

An external electret or condenser microphone must be connected to the 5 pin binder COM connector. The Talkback/Slate is using the same microphone. (see connectors section for pin assignment )

NOTE: The internal switch S3 selects the mic. powering voltage: 48V phantom or 6VDC for electret

7.7.1 Mic 1 to 3

Adjust the send level of the external Communication/Slate microphone that will be fed into the respective COM, PL1 or PL2 lines. from - infinite (Mute) to +10 dB.

SX-ST / SX-SV User Manual