4-6
LS 3070 Product Reference Guide: Maintenance and Specifications
LS 3070 Standard Technical Specifications
ITEM DESCRIPTION
Power Requirements:
Scanner 4.75 to 14 VDC; 210 mA @ 5 VDC Typical.
Base/Charger 5 VDC ± 10% @ 190 mA Typical.
12 VDC ± 10% @ 400 mA Typical.
Scan Repetition Rate Approximately 36 (± 3) scans/sec
(bidirectional)
Start-up Time <50 msec. from scan enable
Data Acquisition Time <110 msec. from scan enable
Skew Tolerance ± 65° from normal
Pitch Angle ± 55° from normal
Decode Depth of Field See LS 3070 Standard Range on page 3-6
Minimum Element Width 0.005 in. .127 mm
Maximum Element Width 0.2 in. 5.08 mm
Print Contrast Minimum 20% absolute dark/light reflectance
differential, measured at 675 nm.
Ambient Light Immunity
Artificial Lighting 450 ft. candles 4844 lux
Sunlight 8000 ft. candles 86112 lux (@8 in. on low
density bar codes)
Durability 6-ft. drop to concrete
Operating Temperature 0° to 40°C 32° to 104°F
Storage Temperature -40° to 60°C -40° to 140°F
Humidity 5% to 95% (non-condensing)
Height 6.3 in. 16 cm
Length 5 in. 12.7 cm
Width 2.8 in. 7.1 cm
CDRH Class I, II