Question:

Can the Truck PAC's battery be replaced?

Answer:

Yes, call Technical Service at (913) 310-1050 (U.S.).

Question:

Can the Truck PAC be recycled?

Answer:

Yes, the environment was one of our main concerns in the development

 

and design of the Truck PAC. Most battery outlets can dispose of this

 

product at its life's end. In fact, your Truck PAC contains a sealed, non-

 

spillable lead acid battery and proper disposal is required by law. See

 

Battery Removal and Disposal Instructions.

Question:

What is the ideal in-use temperature of the Truck PAC?

Answer:

Room temperature. The Truck PAC will also operate at below zero

 

temperatures, however its power will be reduced. Intense heat will

 

accelerate self discharge of the Truck PAC battery.

Question:

I have a regular 10 amp battery charger, can I use it to recharge the

 

Truck PAC?

Answer:

No, only the supplied wall charger should be used.

Question:

Is the Truck PAC goof proof?

Answer:

No, jump starting instructions must be followed. Read and understand all

 

safety and operating instructions in this manual and those found in the

 

owner’s manual of any vehicle being jump started before using your

 

Truck PAC.

Question:

I'm recharging my Truck PAC. Should the green CHARGE COMPLETE

 

light immediately come on?

Answer:

No. First the yellow CHARGING light will come on to indicate the

 

charging process is beginning. Then, the red POWER LEVEL lights come

 

on in sequence as the level of charge increases. Finally, the green

 

CHARGE COMPLETE light will come on, but only when the Truck PAC

 

approaches full charge.

Question:

How long should I charge the Truck PAC?

Answer:

It should be charged for a minimum of 30 hours when new. Your Truck

 

PAC can be left on the wall charger continuously. When recharging with

 

the wall charger, the Truck PAC should be charged for 4 to 6 hours per

 

light that remains unlit when the TEST button is pressed.

Question:

How do I know when the Truck PAC is fully charged?

Answer:

Follow all charging instructions. Remove the Truck PAC from the wall

 

charger and press the TEST button. If all power indicator lights come on,

 

it is fully charged.

Question:

How can I test the battery in my Truck PAC to see if it needs to be

 

replaced?

Answer:

We recommend that you use a 100 amp battery load tester. Load the

 

Truck PAC battery for 6 seconds with a 100 amp load and it should

 

maintain at least 9 Vdc.

Page 8
Image 8
T-Tech ES8000, ES6000 user manual Question

ES6000, ES8000 specifications

The T-Tech ES6000 and ES8000 series represent a remarkable advancement in electronic pressure control systems, designed to meet the rigorous demands of various industrial applications. These models stand out for their exceptional performance, enhanced features, and cutting-edge technologies, making them ideal choices for industries such as pharmaceuticals, food and beverage, and chemical processing.

One of the key features of the T-Tech ES6000 is its advanced user interface, which incorporates a high-resolution touchscreen display. This interface allows for easy navigation through multiple control options, providing users with clear visibility of operational parameters and allowing for real-time adjustments. With its intuitive design, operators can quickly familiarize themselves with the system, leading to improved efficiency in handling complex tasks.

The ES8000 builds upon this foundation, introducing advanced connectivity options such as Bluetooth and Wi-Fi. These features enable seamless integration into existing network environments, allowing for remote monitoring and control from anywhere, significantly enhancing operational flexibility. Operators can receive alerts, manage settings, and gather performance data without being physically present at the machine, streamlining processes and improving response times.

Both models utilize innovative pressure sensing technology, ensuring precise measurements and reliable performance. The advanced sensors incorporated into these units provide real-time data with a high degree of accuracy, allowing users to maintain optimal operating conditions and minimize potential risks associated with pressure fluctuations.

Another standout characteristic of the T-Tech ES6000 and ES8000 is their robust construction. Designed to withstand harsh environments, these systems feature durable materials that protect against corrosion, dust, and moisture. This resilience ensures prolonged service life, reducing downtime and maintenance costs, which are critical factors in high-stakes industrial applications.

Energy efficiency is another significant consideration in the design of these systems. T-Tech has integrated intelligent control algorithms that optimize power consumption, contributing to more sustainable operation without compromising performance. This focus on energy efficiency makes the ES6000 and ES8000 not only cost-effective but also environmentally friendly solutions.

In conclusion, the T-Tech ES6000 and ES8000 series offer a comprehensive suite of features and technologies tailored to meet the demands of modern industrial applications. Their intuitive interfaces, advanced connectivity options, precise pressure sensing, durable construction, and focus on energy efficiency make them exemplary choices for companies seeking to enhance their operational efficiency and reliability.