3.0: UNPACKING AND VISUAL CHECKS
Every Tannoy VNET“ product is carefully tested and inspected before being packaged and leaving the factory. After unpacking your loudspeaker, please inspect for any exterior physical damage, and save the carton and any relevant packaging materials in case the loudspeaker again requires packing and shipping. In the event that damage has been sustained in transit notify your dealer immediately.
3.1: PRELIMINARY RECOMMENDATION
A word of warning on high sound levels - these speakers are capable of generating high output levels over sustained periods of time and such levels, over 95dBspl for 8 hours per day, can eventually cause permanent hearing loss. Since Tannoy loudspeakers have a
For continuous exposure we recommend the occasional use of a sound level meter. This should be capable of integrating the sound level over a period of exposure according to noise control standards and used just to check that noise levels are always within safety limits.
4.0: INTERFACE PANEL
Amplifier & DSP Panel
CAUTION | WARNING |
SHOCK DO NOT EXPOSE THIS EQUIPMENT TO | |
| TO REDUCE THE RISK OF FIRE OR ELECTRIC |
| RAIN OR MOISTURE |
| AVIS: RISQUE DE CHOC |
| OUVRIR. |
THIS CLASS D DIGITAL DEVICE MEETS ALL REQUIREMENTS OF THE | |
CANADIAN | |
COMPLIES WITH PART 15 OF THE FCC RULES. |
|
OPERATION SUBJECT TO CONDITIONS STATED IN THE MANUAL. |
|
THIS EQUIPMENT MUST BE EARTHED
MANUFACTURED IN THE UNITED KINGDOM
• | XLR FEMALE AUDIO INPUT — This is a lockable |
| XLR line input socket for connection to the audio |
| source. Fully Balanced. |
| Pin 2 Hot (+), Pin 3 Cold (+), & Pin 1 Ground. |
• | XLR MALE AUDIO LINK - This is a lockable XLR |
| line output socket to link additional speakers. |
| Fully Balanced. |
| Pin 2 Hot (+), Pin 3 Cold (+), & Pin 1 Ground. |
• | RJ45 NETWORK INPUT - For Control and |
| monitoring functions over RS485. |
A‘LIMIT/NETWORK FOUND’LED displays
DSP limiter action for both output channels. Also duplicates the function of the front mounted network found LED
A green signal present LED, operating at
Power LED
XLR female audio input
XLR male audio link
- LIMIT
- SIGNAL
- POWER
USER DSP
ON - OFF
INPUT | LINK | NETWORK | NETWORK | FUSE |
IN | LINK | T10AL 250V | ||
|
| TEK |
|
|
A ‘NETWORK FOUND’ LED, mounted on the front of the cabinet, software controlled to enable location of specific nodes on the network
A user DSP ON/OFF switch
In the OFF position this will return the loudspeaker to the factory default settings
Fuse Holder
Rugged Neutrik Powercon locking mains connector
• | RJ45 NETWORK LINK - For linking cabinets. |
| Vnet supports free network topology. |
| Cabinets can be daisy chained or linked in a |
| star configuration, or a combination of both. |
• | ROCKER POWER SWITCH — Turns AC power |
| on to the unit (100V — 240V) |
• | FUSE HOLDER — Replace only with 10A 230V |
| |
• | AC MAINS CONNECOR — Neutrik Powercon |
| mains connector (supplied) |
• | USER DSP ON/OFF SWITCH |
• | POWER LED — Blue LED indicates when power |
| has been applied to the speaker. |
C | US |
| LI S |
RJ45 network input | RJ45 network link |
Rocker power switch
• | LIMIT/NETWORK FOUND LED — Also mounted |
| on the front of the cabinet. This can be seen |
| clearly from behind the grill when activated. |
• SIGNAL PRESENT LED
5.0: OPERATION
The range of products are fully integrated designs, all speaker management functions which include driver EQ, dynamic limiting, & crossover functions are carried out within the DSP, therefore the need for external amplification, active crossovers and limiters is not required. The only input from the user is crossover between full range cabinets & subwoofers, and room equalization (if necessary).
When routing audio, units may be daisy chained together by linking the Input/link XLR connectors. It is necessary to have power local to each speaker, as it is not possible to daisy chain the AC power connectors.
6