17
Models 382/RC25 Operatin g Procedures
Step 6
Placet he control switch in the “OFF” posit ion. Place an
empty mix pail beneath the door spout . Open the draw
valve and draw off all of the sanitizing soluti on. When
the sanitizer stops flowing from the door s pout, close
the draw valve.
Figure 28
Step 7
Replace the hopper cover.
Figure 29
Priming
Step 1
Connect the mix delivery line to a container filledwith
mix.
Step 2
Remove the prime plug.
Step 3
With a mix pail beneath the door spout, open the dr aw
valve. Place the fill switch in the “ON” position to allow
fresh product to flow into the freezing cylinder. This will
force out any remaining sanitizing solution. When f ull
strength product is flowing from the door spout,clos e
the draw valve. Allow the mix hopper to fill until the
product rises to the bleed port. Replace t he prime plug.
Figure 30
Step 4
Place the control switch in the “AUTO” pos ition. When
the unit cycles off, the product will be at serving
viscosity.The viscosity (thickness) of the slush can be
adjusted by turning the viscosity adjustment screw
under the control channel. Turn the viscosity
adjustment screw clockwise for a t hicker product, or
counterclockwise for a thinner product. After mak ing
an adjustment, allowt herefrigeration system to cycle
2 or 3 times to accurately evaluate the viscosity.
Figure 31
Note: In order for the refrigeration system to operate,
the fill switch must be in the “ON” position while the
control switch is in the “AUTO” position.