1
Models 382/RC25 To the Installer
050722
Section 1 To the Installer
This machine is designedfor indoor use only.
DO NOT install the machine in an area where
awat er jet could beus ed toc lean orrins e them achine.
Failure to follow this instruction may result in serious
electrical shock.

Installation Instructions

Preparation

Uncrate the condensing and dispensing units. After
inspecting both units for damage, position them in t he
desired locations.

Electrical Connections

Individual power supplies are required for each unit.
Check the data label on each unit for fuse, circuit
ampacity, and electrical specifications. For proper
power connections, refer to the wiring diagram
provided inside of the electrical box.
In the United States, this equipment isintended t o be
installed in accordance with the National Electrical
Code (NEC), ANSI/NFPA 70--1987. The purpose of
the NEC code is the practical safeguarding of persons
and property from hazards arising from the use of
electricity. This code contains provisions considered
necessary for safety. Compliance therewith and
proper maintenance will result in an installation
essentially free from hazard!
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
Stationary appliances which are not equipped with a
power cord and a plug or other device to disconnect
the appliance from the power sourc e must have an
all--poledisconnect ing device with a contact gap of at
least 3 mm installed in the external installation.
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
Beater rotation must be counterclockwis e as viewed
looking into the freezing cylinder of the Model 382
dispenser.
NOTE: The following procedures should
be performed by a trained service techn ician.
To correct rotation on a three-phase unit, exchange
any two incoming power supply lines at the freezer
main terminal block only.
To correct rotation on a single-phase unit, exchange
the leads inside the beater motor. (Follow the diagr am
printedonthemotor.)
Electrical connections are made directly to the splice
box. The splice box is located behind the back panel.
IMPORTANT
Beater rotation on the 380 Series
differs fromother Taylor equipment.