23
Model C300 O perating Procedures
080507
Sanitizing
Note: If a unit is sanitized, and will not be used for
an extended period of time, clean water should be
used to flush all sanitizer from the lines. Remove t he
water from all the lines and components prior to
storage of the unit. Upon return to service, the unit
must be sanitized prior to use.
Step 1
Open the lighted display door. Place the control
switch in the ON position.
Figure 25
Step 2
Prepare an approved 100 PPM sanitizing solution
(examples: 2- 1/2 gal. [9.5 liters] of Kay- 5Ror 2
gal. [7.6 liters] of Stera- SheenR) in a clean, empty
pail. USE WARM WATER AND FOLLOW THE
MANUFACTURER’S SPECIFICATIONS.
Important: Make sure the saniti zer is completely
dissolved.
Step 3
Using an empty bag of syrup, cut the syrup line
connector from the end of the bag.
Figure 26
Step 4
Connect the syrup line to the syrup line connector
that was cut from the syrup bag.
Figure 27
Step 5
With the bag connector attached to the syrup line,
place the syrup line into the pail of sanitizing
solution.
Figure 28
Step 6
Toplace t he left freezing cylinder in the SANITIZE
mode, press the MENU (SEL) key. Move the cursor
by pressing the AUTO (- - >) key until the third line
indicatesRINSE / SANITIZE.
OPERATORMENU
ABCDEFGHI
RINSE / SANITIZE
<- - - - > SEL