28 Model C300Operating Procedures
Draining Product From theFreezing CylinderStep 1
With a pail beneath the door spout, press the
BEATER (- - - ) key. This will allow the beater to
operate and CO2pressure will be maintained to
push the product from the freezing cylinder. Open
the draw valve and drain the product from the
machine until the CO2begins to jet.
Figure 42
Step 2
When all the product has been drained from the
freezing cylinder, close the draw valve and press the
OFF (<- - ) key. Disc ard this product.
Figure 43
Repeat Steps 1 and 2 for the other freezing
cylinder.
RinsingStep 1
Toplace t he left cylinder in the RINSE mode, press
the MENU (SEL) key. Move the cursor by pressing
the AUTO (- - >) key until the third line indicates
RINSE / SANITIZE.
OPERATORMENU
ABCDEFGHI
RINSE / SANITIZE
<- - - - > SEL
Press the MENU (SEL) key. Move the cursor under
“RINSE” by pressing the OFF (< - - ) key twice.
RINSE / SANITIZE
RINSE SANITIZE EXIT
----
<- - - - > SEL
Step 2
Pressing the MENU (SEL) key will give you the
option for rinsing the left freezing cylinder. Move the
cursor under the word “YES”. Pressing the MENU
(SEL) key at this time will start the beater motor and
deliver water and CO2to the left cylinder.
RINSE
LEFT SIDE YES NO
---
<- - - - > SEL
Step 3
Allow the rinse water to flow into the cylinder until it
is approximately 2/3 full. With a pail under the door
spout, open the draw valve and drain the rinse
water. Repeat this procedure until the rinse water
being drawn is clear.
Repeat Steps2 - 3 for the right side.
RINSE
RIGHT SIDE YES NO
---
<- - - - > SEL
When draining is complete, press the OFF (< - - )
key.