29
Model C300 O perating Procedures
080507
CleaningStep 1
Prepare an approved 100 PPM cleaning solution
(examples: 2- 1/2 gal. [9.5 liters] of Kay- 5Ror 2
gal. [7.6 liters] of Stera- SheenR) in a clean, empty
pail. USE WARM WATER AND FOLLOW THE
MANUFACTURER’S SPECIFICATIONS.
Important: Make sure the cleaner is co mpletely
dissolved.
Step 2
Place the syrup line with the old syrup connector into
the pail of cleaner.
Step 3
Toplace t he left freezing cylinder in the SANITIZE
mode, press the MENU (SEL) key. Move the cursor
by pressing the AUTO (- - >) key until the third line
indicates RINSE / SANITIZE. Press the MENU
(SEL) key. Move the cursor under the word
“SANITIZE”.
RINSE / SANITIZE
RINSE SANITIZE EXIT
-----
<- - - - > SEL
Pressing the MENU (SEL) key will give you the
option to sanitize the left cylinder. Move the cursor
under the word “YES”. Pressing the MENU (SEL)
key at this time will start the flow of cleaner/sanitizer
through the syrup system into the freezing cylinder.
SANITIZE
LEFT SIDE YES NO
---
<- - - - > SEL
Repeat this procedurefor the right side freezing
cylinder.
Step 4
Open the prime plugs. Allow each cylinder to fill
approximately 2/3 full. Close each prime plug.
Step 5
Continue filling the freezing cylinders with sanitizing
solution until the solution purges out of each relief
valve, and begins draining into the front drip tray.
The relief valves are located at the top of each mix
tank. Press the OFF (<- - ) key.
Step 6
Press the BEATER (- - -) k ey to agitate the solution
in each freezing cylinder for five minutes.
Figure 44
Step 7
With a pail beneath the door spouts, open the draw
valves and drain all the solution from the the
freezing cylinders. Press the OFF (< - - ) key and
close the draw valves.
DisassemblyStep 1
Be sure the control switch is in the OFF posit ion.
Open the draw valves to make sure all pressure has
been relieved.
Step 2
Open the prime plug. Leave the prime plug open
when removing the freezer door to insure that all
pressure is relieved from the freezing cylinder.
Step 3
Remove the following parts from the freezer and
take them to the sink for brush cleaning.
Shandscrews
Sfreezer doors
Sbeater assemblies and scraper blades
Sdrive shafts
Sfront drip tray
Ssplash shield