31
Model 8756 Operating Proced ures
Step 5
Place an empty pail beneath the door spout. Raise
the prime plug and press the WASH and PUMP
keys.
Figure 62
Step 6
When a steady stream of rinse water is flowing fr om
the prime plug hole in the bottom of the freezer door,
open the draw valve and drain all the rinse water.
Step 7
Once the rinse water stops flowing from the door
spout, close the draw valve and press the WASH
and PUMP keys to stop operation.
Figure 63
Step 8
Disconnect the pressure line from the pressure
switch. Drain the water and then reconnect.
Step 9
Repeat this procedure using clean warm water, until
the water being discharged is clear.
Repeat these steps for the second freezi ng
cylinder.
CleaningStep 1
Prepare a pail of approved 100 PPM cleaning solu-
tion (examples: 2-1/2 gal. [9.5 liters] of Kay-5Ror
2 gal. [7.6 liters] of Stera-SheenR). USE WARM
WATER AND FOLLOW THE MANUFACT URER'S
SPECIFICATIONS.
Step 2
Place the pail of cleaning solution inside the mix
cabinet and insert the suction line.
Figure 64
Step 3
Disconnect the pressure line from the pressure
switch and place it in the pail of cleaning solution.
Step 4
Press the PUMP key. This action will cause the
cleaning solution to be pumped through the air/mix
pump and out through the pressure line. After
approximately 15 seconds, press the PUMP key to
stop operation.
Figure 65
Step 5
Drain and connect the free end of the pressure line
to the pressure switch.