Description of Parts

Model TE400 Shown

Main Features

LCD Screen

1.0” digits display weight.

Tare/Hold Button

When pressed once, the scale will tare (zero out) the weight on the platform. When presses and held for 3 seconds, the weight will continue to display, even after the weight is removed.

lb/kg Button

When pressed, the weight display converts from pounds to kilograms.

On Button

When pressed, turns the scale “ON”.

Off Button

When pressed, turns the scale “OFF”.

Auto Shut Off

Powers off after 2 minutes of non-use.

Low Battery Indicator

Appears on LCD screen when battery is low.

Cord

6' coiled cord.

Control Panel

Can be stationary or mounted to a wall.

Platform

Model TE150 has a stainless steel finish. Model TE400 has a tread painted steel finish.

Before You Begin

1.Remove the scale from its box, along with the control panel and the 120V adaptor.

2.If using the 120V adaptor, plug one end into the receptacle (connector) at the rear of the scale. Insert the other end (the transformer) into a 120V outlet.

Auto Shut-Off Feature

To disable the 2 minute auto-shut off feature:

1.While the scale is off, press and hold “lb/kg”, then press “ON”.

2.The LCD shows “8888”, then “A_oF”. Release the buttons. The scale shows will show “0.0”. The auto-off is disabled.

3.To enable the auto-off feature, repeat Steps 1 and 2. The LCD shows “8888”, then “A_on”, then “0.0”. The auto off is enabled.

Battery Installation

The Digital Receiving Scale operates with 6 “AA” batteries, not included (alkaline recommended).

1.Place the scale upright on a flat surface. Lift the platform cover from the top of the scale.

2.Remove the battery compartment door and insert batteries into the compartment.

3.Replace the compartment door. Replace the platform cover on the scale.

Mounting the Scale

1.Mount the bracket to a wall using 2 screws (not included) that are appropriate anchors for the mounting surface.

2.Lower the control panel into the mounted bracket. Insert the flat tip of the included screws through the round holes in the mounting bracket. Drive the screws into the existing threaded hold in the lower half of the control panel to secure the control panel to the bracket.

YOUR SCALE IS NOW READY FOR USE

Display and Function

General Operation

POWER

To turn the scale on, press the button marked “ON”. The display will first show “8888” followed by “0.0”. The scale is ready for use.

WEIGHING

When the display shows “0.0”, the scale is ready to weigh an object. If the object exceeds the capacity of the scale by more than 5%, the display will show “oooo” (for overload). Until the overload condition is reached, additional objects may be placed on the platform. The display will show the sum of the weights of all the objects. When one of multiple objects is removed from the platform, the weight of the remaining objects will display.

TARE OPERATION

To tare (zero out) a load on the platform (example: the weight of a container), press the “TARE/HOLD” button. The display will show the value “0.0”. During the “TARE” mode, a new item can be added to the platform. The display will show the sum of the weights of the added items. Another item may be added, if desired. The display will show the sum of all additional item weights above and beyond the tared out load.

TARE CAPABILITY

A load of up to the capacity of the scale can be tared (zeroed out), while still allowing the weighing of an additional object, up to the full capacity of the scale.

Example: Model TE150 has a capacity of 150 lbs. If an item weighing 20 pounds is on the scale, and the weight is tared (zeroed out), and additional load or loads of up to 130 lbs can be weighed. (On a 10 pound scale (TE10), a load of 5 lbs (50%) can be tared out.

MINUS WEIGHT

If a weight is tared (zeroed out) and is then removed from the platform, the display will show a minus value.

For example, if a load of 50 lbs is placed on the platform and the “TARE/HOLD” button is pressed, the display will show “0.0”. If the weight is then removed from the platform, the display will show “-50.0”. If the minus value exceeds -99.9 lbs, the display will show “----“.

To reset the minus weight to zero, press the “TARE/HOLD” button.

HOLD OPERATION

The “HOLD” function may be used to lock the weight on the display, even after the load is removed from the platform.

To use the hold function, press and hold the “HOLD” button for 3 seconds. The display will show H-on”, indicating the hold feature is on.

To cancel the hold function, press and hold the “HOLD” button for 3 seconds. The display will show H-oF”, indicating the hold feature is off.

When the Hold function is on, the weight will continue to display, even after the item has been removed from the platform.

UNIT CONVERSION

Press the “lb/kg” button on the front panel to switch between pound and kilogram units of measurement. A small triangle appears in the upper left corner of the display for kg mode, or on the lower left corner for lb mode.

Page 2
Image 2
Taylor TE400, TE150 Description of Parts, Main Features, Before You Begin, Auto Shut-Off Feature, Battery Installation