OPERATION

12 + 15 – Dry/Blend

The Dry/Blend function allows you to use parallel compression. Basically, this means splitting the signal in two and compressing only one part of the signal. With the DRY BLEND switch, you can cycle through three predefined levels of blend and “off”.

Choose between the following settings:

Off:

No blend

Min:

75 % wet and 25 % dry

Med:

50 % wet and 50 % dry

Max:

25 % wet and 75 % dry

The Dry Blend function is especially useful for creating hard sustaining compression without sacrificing the natural attack.

16 – Clipping indicators

If these LEDs flash you have a too hot signal somewhere in the signal processing.

LED A flashing - the input level for input A is too hot. Recalibrate the pedal.

LED B flashing - the input level for input B is too hot. If you are using dual input mode (two instruments) - recalibrate input B. If you are using Engines A+B in serial - reduce the output level of Engine A using the LEVEL knob.

Both LEDs flashing - recalibrate and reduce the general level on both Engines A and B.

13

Page 13
Image 13
TC electronic SDN BHD NDY-1 user manual 12 + 15 Dry/Blend, Clipping indicators