Operating Basics
AFG3000 Series Quick Start User Manual 51
Quick Tips
■When a setting frequency of an output waveform is higher than 4.9 MHz, a divided frequency that is lower than 4.9 MHz
is output from the Trigger Out. See the table below:
5. Burst Mode:
When internal trigger source is
selected, the trigger output is a square
waveform and the rising edge at the
start of each burst period.
When an external trigger source is
selected, the trigger output is high
during the time the trigger input is high.
5
Set frequency of output waveform (MHz) Trigger output frequency (MHz)
4.900 000 000 00 Fs1
1. Fs represents setting frequency of output waveform.
4.900 000 000 01 to 14.700 000 000 0 Fs/3
14.700 000 000 1 to 24.500 000 000 0 Fs/5
24.500 000 000 1 to 34.300 000 000 0 Fs/7
34.300 000 000 1 to 44.100 000 000 0 Fs/9
44.100 000 000 1 to 50.000 000 000 0 Fs/11
50.000 000 000 1 No signal
NOTE. The Trigger Out signal cannot be output when the instrument outputs a continuous signal higher than 50 MHz.
NOTE. When the instrument outputs a modulation waveform, Trigger Output signal cannot be output if you select External