Warranted Characteristics
TDS 500D, TDS 600B & TDS 700D Performance Verification and Specifications 2–21Table 2–10: Warranted characteristics — Signal acquisition system (cont.)
Name Description
A
n
al
og
Ba
ndw
i
dth, DC-
5
0 Cou
ple
d
and Bandwidth selection is FULL,
TDS 500D/700D Volts/Div
TDS 520D, 540D,
724D & 754D
Bandwidth2
TDS 580D &
TDS 784D
Bandwidth2
10 mV/div – 1 V/div DC – 500 MHz DC – 1 GHz
5 mV/div – 9.95 mV/div DC – 500 MHz DC – 750 MHz
2 mV/div – 4.98 mV/div DC – 500 MHz DC – 600 MHz
1 mV/div – 1.99 mV/div DC – 450 MHz DC – 500 MHz
Volts/Div TDS 794D
Bandwidth2
10 mV/div – 1 V/div DC – 2 GHz
Crosstalk (Channel Isolation) 100:1 at 100 MHz and 30:1 at the rated bandwidth for the channel’s Volt/Div setting,
for any two channels having equal Volts/Div settings
Delay Between Channels, Full
Bandwidth TDS 600B: 100 ps for any two channels with equal Volts/Div and Coupling settings and
both channels’ deskew values set to 0
TDS 500D/700D:50 ps for any two channels with equal Volts/Div and Coupling settings
and both channel deskew values set to 0.0 ms.
Input Impedance, DC–1M Coupled 1 M ±0.5% in parallel with 10 pF ±3 pF (DC–50 Coupled only on TDS 794D)
Input Impedance, DC–50 Coupled 50 ±1% with VSWR 1.3:1 from DC – 500 MHz, 1.5:1 from 500 MHz – 1 GHz
Input Impedance, DC–50 Coupled
TDS 794D 50 ±1.25% with VSWR 1.5:1 from 100 MHz – 1 GHz, VSWR 1.7:1 from 1GHz –
2GHz
Input Voltage, Maximum,
DC–1M,
AC–1M, or
GND Coupled
(DC–50 or GND Coupled
TDS 794D only)
TDS 600B: ±300 V CAT II, 400 V peak;
derate at 20 dB/decade above 1 MHz
TDS 500D/700D: ±300 V CAT II, 400 V peak;
derate at 20 dB/decade above 1 MHz
Input Voltage, Maximum, DC-50 or
AC–50 Coupled 5 VRMS, with peaks ±30 V
Input Voltage, Maximum, DC-50
Coupled TDS 794D 5 VRMS, with peaks ±20 V
Lower Frequency Limit, AC Coupled 10 Hz when AC–1 M Coupled; 200 kHz when AC–50 Coupled3
1Net Offset = Offset – (Position × Volts/Div). Net Offset is the nominal voltage level at the oscilloscope input that
corresponds to the center of the A-D converter’s dynamic range. Offset Accuracy is the accuracy of this voltage level.
2The limits given are for the ambient temperature range of 0_C to +30_C. Reduce the upper bandwidth frequencies by
5 MHz for the TDS 600B, by 2.5 MHz for the 500 MHz TDS 500D/700D models, by 5 MHz for the 1 GHz TDS 500D/700D
models, and by 10 MHz for the 2 GHz TDS 500D/700D models for each _C above +30_C.
3The AC Coupled Lower Frequency Limits are reduced by a factor of 10 when 10X passive probes are used.