Operating Basics
VITS100 NTSC VITS Inserter Instruction Manual 2–7
The switch settings for signal selection are listed in Table 2–2. When a switch
segment is thrown to the left (as viewed from the front of the VITS inserter), it is
open; when thrown to the right, it is closed. Open positions are denoted in the
table as 1, and closed are denoted as 0.
Table 2–2: DIP Switch Settings
VITS inserter Action DIP Segment Settings*
1 (5) 2 (6) 3 (7) 4 (8)
Insert Test Signal:
se s
0 1 1 0
0% Black (two
se
tting
s
)1 0 0 1
7.5% Black 1 1 1 0
50% Gray 1 1 0 1
FCC Color Bars 0 0 0 0
FCC Composite 1 0 0 0
Multiburst 0 1 0 1
Multipulse 0 1 0 0
NTC 7 Composite 1 0 1 0
NTC 7 Combination 0 0 0 1
Red Field 1 1 0 0
SIN X/X 0 0 1 0
VIRS 1 0 1 1
Pass Program Video 1 1 1 1
Auto VIRS 0 0 1 1
Insert Source ID 0 1 1 1
* 1 signifies an OPEN switch; 0 signifies a closed switch
Switch Settings