2102 Wireless Communication Module

Section 3 Preparation and Installation

materials that can withstand harsh environments. However, con- tinual exposure to UV light, or periodic submersion should be avoided to extend the life of the components.

Communication between the base and remote modules are rated for distances as great as 1/2 mile (800 meters), line of sight. However, obstructions such as buildings and industrial equipment between the modules may reduce the effective dis- tance.

Typically, the modules are suspended inside a manhole. Sus- pending the module near the opening will protect it from the ele- ments, minimize the chance of submersion, and allow it to be easily retrieved without entering the manhole. In most instances, this location near the opening will allow for successful wireless communication.

Typical communication distances possible using internal antennas are:

Line-of-sight: 1/2 mile (0.8 km)

Inside closed manhole: 100 feet (30m)

3.3 Installation

Note that the Wireless Module must be on top of the stack.

2102 Wireless Module

Carrying Handle

21XX Parameter Module

2191 Battery Module

Figure 3-2 Assembling a Basic System

Connecting the Modules To connect the 2100 Parameter and Battery modules, refer to the following instructions and Figure 3-2.

1.On the top of the Battery Module, remove the cap and stow it on the holder. This exposes the communication connector on the Battery Module.

3-2

Page 20
Image 20
Teledyne 2102 installation and operation guide Wireless Communication Module Preparation and Installation