Telex manual Intercom User Station US2002

Models: US2002

1 40
Download 40 pages 5.87 Kb
Page 18
Image 18

Note: For further information about the cable numbers, see page 14.

Note: A BOP-1000 may be used to rack mount 2 TW-7W splitters.

Figure 6. US2002 Master Headset Station Configuration with 1 Power Supply.

This is a good configuration for smaller intercom systems when you want to operate the US2002 as a master headset station. In this configuration, the PS2001L Combine/Isolate switch is set to the Isolate position. With this setting the 2 intercom channels are completely separated. Typically, a headset is connected to the front panel of the US2002, and the US2002 DIP switches are set to monaural operation (default setting) so that both intercom channels are heard in the monaural headphones (binaural headphone operation is not supported). The PA-KP local power supply is optional. When a PA-KP is connected, the US2002 automatically disconnects from system power that is supplied by the PS2001L. Since the US2002 is not drawing power from the intercom system, more system power is available for additional belt packs, etc.

Intercom User Station US2002 - 18

Page 18
Image 18
Telex manual Intercom User Station US2002