SpectraLink Corporation

T1 Remote Module Installation

 

Link WTS – Link 3000 MCU

5. Configure Remote System

Use the Operator’s Console to enter configuration information for the Remote Expansion Shelves.

5.1Configure Remote Shelf

1.From the Operator’s Console, select F1, Supervisor State Display.

2.Use the arrow keys to highlight the number of the Remote Shelf to be added (2- 20), and press Enter.

3.Select Remote Card Options.

4.Select Edit Remote Cabinet Configuration. The following screen displays.

5.Enter the configuration information for the remote shelf (cabinet). Use the right arrow or mouse to display options. Use the arrow keys to highlight an option, and press Enter to select the highlighted option.

T1 A State: select T1 On to turn on T1 A.

T1 B State: select T1 On to turn on T1 B.

Far Sync Source: Leave the default (None) or select External Port if the far sync source is an external port.

Far Cluster Master: Leave the default (None) if there is only one Expansion Shelf at the remote location. If there is more than one Expansion Shelf at the remote location, select a Cabinet (2-20) as the master shelf for this location.

Net Clocked T1: Leave the default (No) if the T1 is not Net Clocked, select Yes if it is.

Note - enter the name or location of the remote T1 module.

6.Select SAVE to save the information.

Part Number: 72-0059-06-E.doc

Page 22

Page 22
Image 22