Texas Instruments 3000 MCU manual Site Preparation, Required Materials Provided by Customer

Models: 3000 MCU

1 30
Download 30 pages 50.38 Kb
Page 11
Image 11

SpectraLink Corporation

T1 Remote Module Installation

 

Link WTS – Link 3000 MCU

2. Site Preparation

The following steps must be completed before installing the system hardware. If the steps are not already completed refer to each individual section for details.

1.At the local site, install and test Primary Shelf and Expansion Shelves. Refer to Link WTS – Link 3000 MCU: Installation (72-0059-01) for information.

2.At the remote site:

2.1Install a two pair cable to each Base Station as designated on the building floorplans.

2.2Terminate the Base Station wiring with RJ-45 crimp-on plugs at the designated Base Station locations.

2.3Terminate the Base Station wire at the appropriate cross-connect demarc blocks.

2.4Terminate the analog or digital phone extensions from the phone system at the appropriate cross-connect demarc block, and label the block.

2.1Required Materials Provided by Customer

Rack - the shelves are designed to fit into a 19 inch mounting rack. Each shelf measures 15” high by 19” wide by 9” deep, and weighs approximately 35 pounds fully loaded. See Prepare Location for Shelves, in the Link WTS – Link 3000 MCU: Installation document.

Backboard space – as an alternative to rack mounting, the shelves can be wall mounted to ¾” plywood securely screwed to a wall.

Screws – required to mount the shelves to the wall, or to secure it in the rack. For wall mount, six #10-5/8” panhead wood screws (or similar device) are required. For rack mount, screws required are determined by the rack requirements; typically 10-32 or 1/4-20.

RJ-45 Cable - for network clocked T1 facilities, an RJ-45 cable is required to connect the designated Master Clock T1 Module to the Intershelf Junction Panel.

Part Number: 72-0059-06-E.doc