Troubleshooting Procedures 5-27

Figure 5-11 Battery Charger Interface Troubleshooting Diagram

System Fails to Boot:Battery Charger Interface Checks
DC_IN=19V Check F1, T3
U4=5V Check D18
Charge Battery 1 or
Charge Battery 2
Check Charger Control
Board (RBC3) U1, D8,
D7
Check Battery Pack
Voltage & Temp

END

Yes
No
Yes
Yes
No
No
Plug-In AC Adapter
10