Total Harmonic Distortion + Noise

Total Harmonic Distortion + Noise

5.1 Total Harmonic Distortion + Noise

The APA100 has excellent total harmonic distortion + noise (THD+N). Figure 5−1 and Figure 5−2 show the THD+N versus frequency, and Figure 5−3 and Figure 5−4 show THD+N vs output power. A 30-kHz bandwidth limit was used on the audio precision to limit switching frequency from affecting the measurement.

Figure 5−1. APA100 THD+N vs Frequency With 4- W Load

THD+N − Total Harmonic Distortion + Noise − %

100

10

1

0.1

0.01

20

VCC = 29.5 V

PO = 70 W

PO = 40 W

PO = 10 W

PO = 1 W

100 200

1 k 2 k

20 k

f − Frequency − Hz

 

Figure 5−2. APA100 THD+N vs Frequency With 8- W Load

THD+N − Total Harmonic Distortion + Noise − %

100

10

1

0.1

0.01

20

VCC = 29.5 V

PO = 40 W

PO = 20 W

 

 

 

 

PO = 10 W

 

 

 

 

 

 

 

 

 

 

 

 

PO = 1 W

100 200

1 k 2 k

20 k

f − Frequency − Hz

 