Emulation Timing Calculations
E-9
Design Considerations for Using XDS510 Emulator
In a multiprocessor application, it is necessary to ensure that the EMU0 and
EMU1 lines can go from a logic low level to a logic high level in less than 10
µs, this parameter is called rise time, tr. This can be calculated as follows:
tr= 5(Rpullup × Ndevices × Cload_per_device)
= 5(4.7 k ×16×15 pF)
= 5(4.7 ×103 ×16 ×15 = no –12 F)
= 5(1128 ×10 –9
= 5.64 µs