Quick Start List for Stand-Alone

2.3 Quick Start List for Stand-Alone

Follow these steps to use the TPA0103 EVM stand-alone or connect it into existing circuits or equipment. Connections to the TPA0103 module header pins can be made via individual sockets, wire-wrapping, or soldering to the pins, either on the top or the bottom of the module circuit board. Numbered callouts for selected steps are shown in Figure 2±2 and details appear in Chapter 3.

Figure 2±2. Quick Start Module Map

4

C7 R10 RHP

GNDR8 C6

RIN

GND

R15

 

 

C8

 

R18

 

R16

 

GND

 

C3

 

 

LIN

C1

R1

GND

 

 

 

LHP

C2

R3

 

VDD

 

GND

R11 ROUT+

 

+

 

 

 

GND

R7

C11

 

 

S5

R14

 

S3

COUT±

 

 

HP/L*

R9

 

 

S4

 

 

 

C9 C10

 

MODE A

 

 

 

 

R17

 

 

 

R12

 

 

 

 

MODE B

U1

 

 

 

 

 

 

TPA0103

EVM

R4

 

 

 

 

 

REV. A

 

C12

 

Lit.# SLOP103

R13

C5

S2

 

SDWN

 

 

 

 

 

R2

±3

S1

R6

 

COUT+

 

 

 

 

GND

 

 

R5

 

 

 

 

 

 

LOUT+

 

009228

 

 

 

 

 

 

 

 

3

-Power supply

1)Ensure that all external power sources are set to OFF.

2)Connect an external regulated power supply set to 5 V to the module VDD and GND pins taking care to observe marked polarity.

-TPA0103 EVM jumpers

Setting the EVM for Center or L/R as indicated in the table below will cause the EVM to operate in the center channel BTL mode (speaker).

3) Set the jumpers on the TPA0103 EVM as indicated in Table 2±5.

Table 2±5. TPA0103 EVM Stand-Alone Jumper settings

EVM OUTPUT MODE

S1

S2

S3

S4

S5

 

 

 

 

 

 

Center or L/R

ON

ON

OFF

OFF

OFF

Note: OFF = Open, ON = Closed

-Inputs and outputs

4)Ensure that signal source level adjustments and EVM gain controls, R13, R14, and R17, are set to minimum.

5)Connect the audio source to the module IN+ and GND pins, taking care to observe marked polarity.

6)Connect the SDWN pin to VDD through a Normally Open switch.

7)Connect a 4-Ωto 8-Ωspeaker to the module COUT+ and COUT± pins.

-Power-up

8)Verify correct voltage and input polarity and set the external power supply to ON.

9)Adjust the signal source level and EVM gain levels as needed.

2-4

Quick Start

Page 14
Image 14
Texas Instruments manual Quick Start List for Stand-Alone, ±5. TPA0103 EVM Stand-Alone Jumper settings