36
4.4 Set Black Mark Sensor as Media Sensor and Calibrate the Black Mark Sensor
Please follow the steps as below.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns green/amber after 5 green blinks. (Any
green/amber will do during the 5 blinks).
The LED color will be changed as following:
Amber red (5 blinks) amber (5 blinks) green (5 blinks)
green/amber (5 blinks) red/amber (5 blinks) solid green
4.5 Set Gap Sensor as Media Sensor and Calibrate the Gap Sensor
Please follow the steps as below.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns red/amber after 5 green/amber blinks. (Any
red/amber will do during the 5 blinks).
The LED color will be changed as following:
Amber red (5 blinks) amber (5 blinks) green (5 blinks)
green/amber (5 blinks) red/amber (5 blinks) solid green
4.6 Skip AUTO.BAS
TSPL2 programming language allows user to download an auto execution file to
flash memory. Printer will run the AUTO.BAS program immediately when turning on
printer power. The AUTO.BAS program can be interrupted without running the
program by the power-on utility.
Please follow the procedures below to skip an AUTO.BAS program.