4.1Humidity/Fan Control Panel WITHOUT Fresh Air Ventilation or Damper
The humidity/fan control panel automatically controls the humidity of the living space. The humidity/fan control panel contains an adjustable humidity control and a fan switch. The panel has a cover that must remain open to the air within the living space for accurate humidity sensing. Position the fan switch ON when the home is occupied. This filters and circulates air throughout the home. For humidity control operation refer to section 4.2.
Figure 1: Humidity/Fan
Control Panel
4.1A Humidity/Fan Control Panel WITH Fresh Air Ventilation and WITHOUT Damper
The humidity/fan control panel automatically controls the humidity of the living space. The humidity/fan control panel contains an adjustable humidity control and a fan switch. The panel has a cover that must remain open to the air within the living space for accurate humidity sensing. Position the fan switch “ON” when the home is occupied. This filters and circulates air throughout the home. Outside air is introduced whenever fan is “ON.” Manual operation of fan filter switch controls outside air and ventilation. Since the fan operates whenever the
4.1B Humidity/Fan Control Panel WITH Fresh Air Ventilation AND Damper
MIn this configuration, a motorized damper has been installed in the fresh air duct. When the fan/filter switch is in the “OFF” position, the damper is closed. The
When the fan/filter switch is in the “ON” position, the motorized damper will open and the fan will run, introducing outside air. The unit may or may not be dehumidifying in the ventilation mode, depending on the humidity control setting. See Section 4.2 for humidity control operation.
4.1C Ventilation Timer and Humidity Control WITH Fresh Air AND Motorized Damper
Refer to sections 4.2 through 4.7.
Figure 2: Ventilation Timer
and Humidity Control Panel
4.1D DEH 2000 Digital Controller WITH Fresh Air AND Damper
Refer to Section 5.
4.1E DEH 2000 Digital Controller WITHOUT Fresh Air
Refer to Sections 5 through Section 5.2G only.
4.2 Humidity Control Adjustment
Set the humidity control to the desired humidity level for the home. Turning the knob clockwise results in a drier setting. See the back of the control panel cover for set points. The dehumidifier will run continuously until the relative humidity (RH) is reduced to the humidity control dial setting. Setting the humidity control to lower RH levels will NOT increase the unit's dehumidification rate; the unit will simply run longer to reduce the area's RH to the setting. The
Figure 3: Humidity Control
Adjustment Knob
4.3 Fan/Filter Switch
Turning ON the fan/filter switch will cause the
Figure 4: Fan/Filter Switch
4.4 Ventilation Timer
The ventilation timer controls the impeller fan and the motor- ized fresh air damper. When the ventilation timer is activated, the