5.3I Temperature Cutout Programming

FOR HVAC INSTALLER AND HOMEOWNER

2.Press the program enter key to toggle to the “open for” setting. Using the up/down “RH” keys, change the duration that the damper will ventilate fresh air.

3.Press the program enter key to toggle to the “closed for” setting. Using the up/down “RH” keys, change the duration that the damper will remain closed between ventilation.

For the example given, starting at 8:00AM in the morning, the control will ventilate fresh air for 15 minutes then stop for 15 minutes. This schedule of 15 minutes open; 15 minutes closed will continue until the start time of the night schedule.

Press “program enter” again to go to the “MON-FRI” night schedule. Repeat the steps listed above for this and the “SAT-SUN” day and night schedules.

When you return to the main program menu, use the up/down “RH” buttons to select “run program.”

Press “program enter” to run the program. The display will appear as follows:

Vent schedule

Program

on time/off time

RUN mode

5.3I Temperature Cutout Programming

Ultra-Aire units produce heat when dehumidifying. Depending on outside conditions, the ventilation function may introduce warm air into the space. Occasionally, the operation of the Ultra-Aire may produce enough heat to drive temperatures up. The temperature cutout feature disables all Ultra-Aire operations if temperatures reach cutout setpoint. In most installations this

feature will not need to be used. If temperature cutout is desired, program the setpoint by pressing the “program enter” button. Press RH until “temp cutout” is flashing. Use “RH” up or “RH” down to adjust setpoints.

5.3J Default Settings

Upon initial power-up or after prolonged power outages (more than 30 minutes), the DEH 3000 is programmed with the following defaults. A space is provided to make note of user inputs.

Setting

Default

My Setting

 

 

 

RH setpoint

50%

__________

Ventilation Operation

Closed

__________

Fan Setting

Auto

__________

Temp Cutout

80%

__________

If you have questions about the

DEH 3000, please call Therma-Stor LLC at 1-800-533-7533 or email us at sales@thermastor.com