Thermador Electrical installation, CIT304, Models, CIT365 and CIS365 models

Models: CIS365

1 35
Download 35 pages 56.4 Kb
Page 10
Image 10
Electrical installation

Electrical installation

Electrical requirements

You can

find

the

identification plate with

the electrical specifications on the

 

underside

of

the

appliance. The junction

box must be located within 3 feet

(~900 mm) of the cooktop connection. It should be easily accessible for service purposes.

3 1/4º max (79 mm) + Fitting/Conduit 1º (23 mm)

12º approx. (300 mm)

Connection (ºJº) box

1º min (26 mm) air clearance

Conduit approx. 3 ft. (~900 mm)

Power supply

CIT304

Models...

 

40

Amp

circuit breaker

 

240

Volts, 3

Wire,

60

Hz

208

Volts, 3

Wire,

60

Hz

All with 39"

(1m)

flexible

conduit (included)

 

 

 

 

 

 

CIT365 and CIS365 models...

50 Amp circuit breaker

240 Volts, 3 Wire, 60 Hz

208 Volts, 3 Wire, 60 Hz

All with 39" (1m) flexible conduit included