Electrical installation
Electrical requirements | You can | find | the | identification plate with | the electrical specifications on the |
| underside | of | the | appliance. The junction | box must be located within 3 feet |
(~900 mm) of the cooktop connection. It should be easily accessible for service purposes.
3 1/4º max (79 mm) + Fitting/Conduit 1º (23 mm)
12º approx. (300 mm)
Connection (ºJº) box
1º min (26 mm) air clearance
Conduit approx. 3 ft. (~900 mm)
Power supply
CIT304 | Models... |
| |||
40 | Amp | circuit breaker |
| ||
240 | Volts, 3 | Wire, | 60 | Hz | |
208 | Volts, 3 | Wire, | 60 | Hz | |
All with 39" | (1m) | flexible | conduit (included) | ||
|
|
|
|
|
|
CIT365 and CIS365 models...
50 Amp circuit breaker
240 Volts, 3 Wire, 60 Hz
208 Volts, 3 Wire, 60 Hz
All with 39" (1m) flexible conduit included
11