Thermador HS-HST-HSB Wiring the HOOD with an IntegralVentilator, Final installation steps

Models: HS-HST-HSB

1 17
Download 17 pages 226 b
Page 15
Image 15
Wiring the HOOD with an IntegralVentilator:

Wiring the HOOD with an IntegralVentilator:

Warning: Turn off electricity at the service panel before wiring the unit.

1.Connect the Integral Ventilator molex plug connector to the connector present inside the hood as shown in Figure 9 or

Figure 10.

2.Remove the j-box cover as shown in Figure 11.

3.Remove 1 of 2 knockouts and install 1/2” conduit connector in j-box.

4.Run black, white, and green wires (#14 AWG) in 1/2” conduit from power supply to j-box.

5.Connect black, white, and green wires from power supply to black, white, and green/ yellow wires in j-box respectively.

6.Close j-box cover.

Final installation steps

7.Only HSB30 and HS30 Series hoods: fit the side mould on the right side, and fix it with 3 screws as shown in Figure 12.

8.Replace filters as described in the Care & Use section of this manual.

Turn power on at service panel. Check operation of the hood.

 

From Control

 

Panel

 

Motor connector

Figure 10

VTN 420 or VTN 620

From control panel

Figure 11

Figure 12

Page 15

Page 15
Image 15
Thermador HS-HST-HSB Wiring the HOOD with an IntegralVentilator, Remove the j-box cover as shown in Figure