Thermador VCI2 Installation Procedure, Unpack Hood, Prepare ductwork, Ducting Recommendations

Models: VCI2

1 28
Download 28 pages 57.13 Kb
Page 7
Image 7
Ducting Recommendations

5/8”

(15

mm)

 

 

 

 

 

 

 

min.

 

 

 

 

7/8”

 

 

13

 

mm)

 

 

.3

 

 

(325

 

 

 

Installation

. min mm) (15 5/8”

27

5/8”

(700.

3

 

mm)

5/8” (16 mm)

 

Figure 8: Housing Cutout Dimensions - 28 3/4” (73 cm) models

Ducting Recommendations

The unit is for ducting to the outside; it cannot be used in conjunction with a recir-

 

culation unit.

 

For the most efficient air flow exhaust, use a straight duct run or as few elbows as

 

possible.

 

Do not use flex ducting. Always use metal ductwork with a diameter of 6” (150

 

mm).

 

COLD WEATHER installations should have an additional backdraft damper

 

installed to minimize backward cold air flow and a nonmetallic thermal break to

 

minimize conduction of outside temperatures as part of the ductwork. The damper

 

should be on the cold air side of the thermal break. The break should be as close

 

as possible to where the ducting enters the heated portion of the house.

 

Always install a metal vent cover where the ductwork exits the house.

 

Make-Up Air: Local building codes may require the use of make-up air systems

 

when using ducted ventilation systems greater than specified CFM of air move-

 

ment. The specified CFM varies from locale to locale. Consult your HVAC profes-

 

sional for specific requirements in your area.

Installation Procedure

 

WARNING: To avoid electrical shock hazard, before installing,

 

switch power off at the service panel and lock the panel to prevent the

 

power from being switched on accidentally.

Unpack Hood

Pull hood from outer packaging. Remove and discard all packaging materials.

 

Remove filter and set aside (See Use and Care manual for removal instructions).

Prepare ductwork

Install one-way damper so that the flap opens up (snaps into place). Note: verify

 

that the flap opens up (toward the ceiling) before continuing. If necessary, install

 

thermal break and additional backdraft damper.

English 5

Page 7
Image 7