OH8FA119D60B
OH6FA072D48B
OH6FA072DV4B
OH6FA072D48R
CONTENTS
Fuel
Configuration
Model Number Digit
Heat Exchanger Identifier
χWARNING AND CAUTIONS
I. SAFETY SECTION
SERVICE PERSON. See Page
χCAUTION:DO NOT ATTEMPT TO START THE BURNER WHEN
Page
A. CODES AND CLEARANCES
a. Combustible material
b.Non-combustiblematerial
FROM
TYPE OF
MODEL NO.1
SIDES OF
A. CHIMNEY
1. PROPER CHIMNEY SIZE
2. PREVENTION OF CHIMNEY CONDENSING
4. PROPER VENT CONNECTOR PIPE/CHIMNEY CONNECTION
3. PROPER CHIMNEY HEIGHT
8. NO INTERCONNECTED CHIMNEY FLUES
7. TIGHT CLEAN-OUTDOORS AND CONNECTIONS
6. TIGHT JOINTS
B. FLUE PIPE CLEARANCES, SIZING AND TYPE
A.Equal the required clearance with no protection
B. VENTING
ROTATION OF FRONT FLUE ELBOW
C. DRAFT REGULATORS
D. DUCT WORK/AIR CONDITIONING
Note: Do not use with Direct Vent application
Airflow Requirements and Sizing of Duct Work
Page
7.The supply and return air ducts, or flexible joints, should be carefully secured and sealed to the appliance housing to prevent air leakage from, or into, the duct system. For best performance, insulate the outside surfaces of the ducts to reduce heat loss from, or heat gain to, the ducts
E. Air Filter Mounted External to Furnace
1.1 X TR TEMPERATURE RISE, F = HEATINGCFM
1.HEATING CFM HEAT OUTPUT OF FURNACE BTUH
Connect the return air plenum to the filter rack and slide the filter into place. Dimensions for adapting the return air plenum to the filter rack are provided See Fig. 10a & 10b
Filter Type
F. LIMIT POSITION AND LOCATION
Maximum
Air Velocity
G. BURNER INSTALLATION
H. BURNER SPECIFICATIONS AND APPLICATIONS
DO NOT CHANGE POSITION OF THE CHAMBER
+ INSULATOR S = SLEEVE OR N = NONE
EQUIVALENT HEAT
OIL NOZZLE CAPACITY CHART
NOZZLE SIZE
EFFECTIVE HEATING
CAPACITY
MOUNTING THE 2-STAGERIELLO BURNER
2 STAGE FIRING RATES
FIRING
I. OIL TANK AND PIPING
J. OIL FILTER
K. ELECTRICAL WIRIING
Model
Assembly
Maximum
115 VAC
Thermostat Anticipator Setting
Preferred method of adjustment
L. Blower Motor Speed Selection
Heating Speed Set-ups
OH6FA072DV4
Furnace Motor Current
Heating Speed Set-ups
OH8FA119DV5
Draw Amps / Watts vs
Figure 18-2:ECM 2-stageblower motor speed chart
Heating Speed Set-ups 2 – Stage OH6FX072DV4
Draw Amps / Watts vs
Cooling Speed Set-ups OH6F*072DV4
Furnace Motor Current
External Static Pressure in W.C
Draw Amps/Watts vs
Cooling Speed Set-ups OH8FA119DV5
Furnace Motor Current
External Static Pressure in W.C
OH6FA072D48
OH8FA119D60
Speed vs. color code for PSC Motor Low = Red
Med-Low= Blue Med-High= Yellow High = Black 34
M. BLOWER CONTROLLER INFORMATION FOR PSC MOTOR
TERMINAL DEFINITIONS & FIELD WIRING
A. Inputs
B. Outputs
C. Operating Modes
Heat Mode
PSC TROUBLE SHOOTING
DIAGNOSTIC FEATURES
For Your Safety Read Before Operating
N. STARTUP PROCEDURES
Operating Instructions
i.STOP! Read the safety information above
2. Adjustment of Burner Combustion
To Turn Off Oil to Appliance
COMBUSTION HEAD SETTING FOR 2-STAGERIELLO BURNER
AIR DAMPER ADJUSTMENT
TURN TO THE RIGHT: SIGN +
TURN TO THE LEFT: SIGN
1st STAGE ADJUSTMENT
2nd STAGE ADJUSTMENT
3. Adjustment Of Heat Input Rate
Notice: Minimum return air temperature is 55F
4. Setting Supply Air Temperature Rise
5. Checkout Procedure
χCAUTION:DO NOT ATTEMPT TO MAKE REPAIRS YOURSELF
III. USERS INFORMATION SECTION
C. INSPECTION AREAS
χCAUTION:DO NOT ATTEMPT TO START THE BURNER WHEN
E. FILTER CLEANING AND LOCATION
D. STARTING THE BURNER
IV. INSTALLERS INSTRUCTIONS TO USER
B.HEAT EXCHANGER
V. DEALER MAINTENANCE
A.GENERAL INSPECTION
SAFETY DURING SERVICING AND INSPECTION
C. HEAT EXCHANGER CLEANING INSTRUCTIONS
SERVICE PERSON
Figure 24 Heat Exchanger Clean-Outs
Vacuum Hose Length OH6 8FT OH8 8FT
E. SUPPLY/RETURN AIR BLOWER
Filter maintenance procedure
D. ELECTRICAL SYSTEM
F. SUPPLY/RETURN AIR FILTER
Filter replacement
G. EXTENDED APPLIANCE SHUTDOWN
ON STARTUP
2.Remove the furnace front door
Beckett Burner
VII. TROUBLESHOOTING
PERSONNEL, AND NOT BY THE FURNACE OWNER
Riello Burner
B. CAD CELL CHECKOUT PROCEDURE
A. DIAGNOSTICS
Diagnostic Features
Number of flashes
Page
VIII. Sequence of Operations Flow Chart
Page
IX. Trouble Shooting Flow Chart
Page
Page
Page
Page
CUSTOMER
HEATING
SYSTEM
Appendix – A Replacement Parts
Replacement Parts for OH6FA072D
Replacement Parts for OH8FA119D
Appendix – B Wiring Diagrams
OH6FA072D48 PSC Wiring Diagram 71
OH6FA072DV4 ECM Wiring Diagram
OH6FX072DV4 ECM 2-StageWiring Diagram
OH8FA1119D60 PSC Wiring Diagram 74
OH8FA1119DV5 ECM Wiring Diagram