Thermo Products OH8FA119D60B F. Limit Position And Location, Maximum, Filter Type, Air Velocity

Models: OH8FA119D60B OH8FA119DV5B OH6FX072DV4R OH6FA072DV4N OH6FA072D48N OH8FA119D60R OH8FA119DV5R

1 79
Download 79 pages 47.9 Kb
Page 20
Image 20
Maximum

 

Maximum

 

 

Filter Type

Air Velocity

Model Number

 

(ft/min)

OH6

OH8

*Thermo Products

600

384 in²

480 in²

Supplied Permanent

 

 

 

Standard

500

461 in²

576 in²

Permanent

 

 

 

Disposable

300

768 in²

960 in²

 

 

 

 

Table 4: Minimum Required Filter Area (in square inches)

*The Thermo Products supplied filter can be cut to size to fit other filter retention systems as long as the minimum size requirement is met.

NOTICE: Any internal stiffeners used in the filter must not be removed, although they can be cut to size as needed.

F. LIMIT POSITION AND LOCATION

χWARNING: The predetermined limit locations on all of the Thermo Pride oil fired furnaces have been tested and approved by Thermo Products, LLC. Any attempt to relocate these safety controls or replace these safety controls with a control that is not approved, or is incompatible, may result in personal injury, substantial property damage or death.

The unit listed in the table below must have the limit control installed at the time of unit installation.

TABLE 5: Installation location of the fan and limit control for each furnace

Fig. 11: Limit location for OH6 & OH8

17